GB
Application
Single-hole mixer suitable for:
• direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Operation with unpressurised storage heaters
(= displacement water heaters) is not possible.
Safety notes
• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable
for indoor use.
• In the case of damage to the external connection cable
of the power supply unit, it must be replaced by the
manufacturer or the manufacturer's customer service
department or an equally qualified person, in order to
prevent a hazard.
• The switched-mode power supply connector must not
be directly or indirectly sprayed with water for cleaning
purposes.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
• Flow pressure:min. 0.05 MPa / recommended 0.1 - 0.5 MPa
• Operating pressure:
• Test pressure:
If static pressure exceeds 0.5 MPa, a pressure-reducing valve
must be fitted.
• Flow rate at 0.3 MPa flow pressure:
• Temperature
Hot water inlet:
Recommended (energy saving):
Fitting with switched-mode power supply (36 269):
• Voltage supply:
100-230 V AC 50-60 Hz/6.75 V DC
• Power consumption:
Fitting with battery (36 271):
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range according to Kodak Gray Card, grey side,
8x10", landscape (factory setting):
• Type of fitting protection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and
rated current.
General functions
• Thermal disinfection:
• Remaining battery capacity:
3
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
Additional instructions regarding programme
overview, programme selection and activation of
the functions can be downloaded under
www.grohe.com/tpi/euroeco-ce.
Special accessories
Further settings and special functions are available
via the infrared remote control (Prod. No. 36 206).
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
max. 1 MPa
1.6 MPa
Flush pipes thoroughly before and after installation
(observe EN 806).
approx. 7.5 l/min
Fitting
Refer to the dimensional drawing and Fig. [1] on fold-out page I.
max. 70 °C
Fasten fitting to wash basin, see Figs. [2] and [3].
60 °C
Connection
1. Attach solenoid valve (A) to nipple (B), assemble two-piece
clip (C) at the connection point and engage, see Fig. [4].
2.4 W
2. Attach solenoid valve (A) to the connection hose,
see Fig. [5].
3. Install filter (D) in nipple (B), see fold-out page II, Fig. [6].
4. Install solenoid valve (A) via nipple (B) on the service valve,
ensuring that no installation forces are applied to the
solenoid valve.
60 s
5. Connect solenoid valve cable (A1) to electronics cable (E1),
1 s
see Fig. [7].
approx. 12cm
Connecting the voltage supply
IP 59 K
Prod. No. 36 269:
1. Connect plug-in connector between electronics cable (E2)
and power supply unit (F), see Fig. [8].
A
2. Connect voltage supply via power supply unit (F).
2
2500 V
Prod. No. 36 271:
100 °C
1. Secure bracket (G1) using screws and plugs, see Fig. [9].
2. Insert battery (G2) in battery housing (G4) and fit lid (G3).
Observe correct polarity.
3. Connect plug-in connector between electronics cable (E2)
and battery housing (G), see Fig. [10].
4. Engage battery housing (G) in bracket (G1).
Open hot and cold water supply and check connections
activatable
for watertightness.
readable
activatable
deactivated
3.5 min