Electrical connections

Transmitter
1
Pin
Wire
Function
1
Brown
Supply
2
White
Not used
3
Blue
Supply
Not used
4
Black
1
Colors according to ABB Jokab Safety standard cables.
Receiver
1
Pin
Wire
Function
1
White
TEST/RESET*
2
Brown
Supply
3
Green
Not used
4
Yellow
EDM
5
Grey
OSSD1
6
Pink
OSSD2
7
Blue
Supply
8
Red
Not used
1
Colors according to ABB Jokab Safety standard cables.
2
Automatic/manual reset and EDM functions are configured with dip-switches.
2TLC172294M0201 Rev B
2015-09-17
Connection to
+24 VDC
0 V
Auto. Reset with no function
Auto. Reset with Acknowledge
function or Alignment mode
Manual Reset
Function used/activated
2
Function not used/deactivated
Connection to
+24 VDC
NC contact to +24 VDC
NC contact to +24 VDC
+24 VDC
NC contact of force-guided relay
Not connected
Safety control module for ex.
Safety control module for ex.
0 V
4