Diagnostic functions
The operator can evaluate the main causes of system stops and errors, using four LEDs on the receiver and two
LEDs on the transmitter.
Transmitter:
Display
ON green
Flashing yellow
OFF
OFF
ON green
OFF
Receiver:
Display
OFF
Flashing yellow
Flashing red
Flashing yellow
OFF
OFF
Flashing red
Flashing yellow
OFF
Flashing yellow
OFF
Flashing yellow
OFF
OFF
OFF
Flashing yellow
OFF
OFF
OFF
OFF
2TLC172294M0201 Rev B
2015-09-17
Description
Generic error on transmitter
side
Power supply error
The power supply voltage is
outside the allowed range
Main microprocessor error
Description
OSSD error
EDM error
Microprocessor error
Optical error
Power supply error
Main microprocessor error
10
Action
- Check the power supply; if the error persists,
contact your ABB Jokab Safety
representative and replace both units.
- Check the power supply; if the error persists,
contact your ABB Jokab Safety
representative.
- Check the power supply; if the error persists,
contact your ABB Jokab Safety
representative.
Action
- Check the wiring and connections of the
OSSD outputs. Make sure that there is no
short-circuit between them or with the supply
voltage. See also the instruction manual
paragraph "Connection examplesError!
Reference source not found.".
- Check that the load characteristics are in
accordance with the Technical data (see the
instruction manual paragraph "Technical
data").
- Check the wiring and connections of the
EDM, as well as the time sequence (see the
instruction manual Time chart).
- Switch the devices off and on; if the error
persists, replace the external switching
device.
- Check the position of the configuration dip-
switches. Dip-switches 5-8 should be in the
same position as dip-switches 1-4.
- Switch the devices off and on; if the error
persists, contact your ABB Jokab Safety
representative.
- Check the alignment.
- Switch the devices off and on; if the error
persists, contact your ABB Jokab Safety
representative.
- Check the wiring and connections of the
power supply. Check that its value is within
the allowed range.
- Switch the devices off and on; if the error
persists, contact your ABB Jokab Safety
representative.
www.abb.com/jokabsafety