Warning
Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations made by
others for any reason or for the use of non-original accessories or materials.
All the products comply with the requirements of Directive 2006/95/EC (which replaced Directive 73/23/EEC and subsequent amendments), as certifi ed by the CE mark they carry.
Do not insert objects or pour liquids into the device.
Installation, mounting and assistance procedures for electrical devices must only be performed by specialised electricians.
Cut off the power supply before carrying out any maintenance work.
This document may not be reproduced, even in part, without the express written consent of Comelit Group spa. The brands and commercial names appearing in this publication
remain the property of their respective owners.
For complete ViP system installation and wiring information, please refer to the relevant technical manual, which is also available from the website
www.comelitgroup.com.
KIT CONTENTS
1 Internal unit
Backplate
1 Power supply unit for internal unit
Floor distributor
Apartment Gateway
*
1 Ikall external unit
1 Power supply unit for external unit
The "Intercall Vip" application is available to download from Google play (for Android devices) and the Apple Store (for IOS devices).
DEFAULT: the ViP address of internal unit Art. 6202WK is set to 00000001 "Master", the ViP address for external unit Art. 4894I
/ Art. 4894IM is set to 00000100.
The IP address of gateway Art. 1456 and Art. 1456S is set to 192.168.1.200.
*
For apartment gateway wiring confi guration, please refer to the Technical Manual for Art. 1456 and Art. 1456S.
**
An additional pre-programmed Ikall metal external unit Art. 4895IM (and corresponding power supply unit for external unit
Art. 1595) is available to purchase separately.
Guide to fi tting a network cable for connecting the PC to Comelit switch Art. 1440 or between PC and POE output
The recommended cables are:
• UTP (Unshielded Twisted Pair): not protected from electromagnetic interference, maximum length 100 metres. We recommend the use of a
Panduit cable code NUL5C04BU-CE.
• STP (Shielded Twisted Pair): similar to the UTP but with a metal sheath.
The UTP and STP can fall into various categories. Category 5 (CAT 5) cables or greater must be used for the ViP system.
The tools required for fitting are as follows:
• 6-P 8-P crimping pliers.
We recommend using 8-pole Panduit pliers code MPT5-8A.
• 2 RJ45 connectors for each section of cable.
We recommend using Panduit connectors code MP588-L.
8511I
8511IM
Art. 6202WK
Art. 6202WK
Art. 6231
Art. 6231
Art. 1441B
Art. 1441B
Art. 1440
Art.1440
Art.
4894IM**
Art. 4894I
(Ikall)
(Ikall metal)
Art. 1595
Art. 1595
Port
Pin 1
8512IM
8513IM
Art. 6202WK
Art. 6231
Art. 1441B
Art. 1441B
Art. 1456S
Art. 1456
GATEWAY SLAVE
GATEWAY MASTER
Art.
4894IM**
Art.
(Ikall metal)
(Ikall metal)
Art. 1595
Art. 1595
RJ45 PINS
Connector
Pin 8
Pin 8
Pin 1
4894IM**
5