Programming; Programming Button Description; End Limit Setting And Self-Learning; Memorising Remote Controls - SOMFY Dexxo Optimo RTS Manual De Instalación

Ocultar thumbs Ver también para Dexxo Optimo RTS:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PROGRAMMING

Programming button description

+
SET
P0
P1
Indicator light key:
off
fl ashing
on

End limit setting and self-learning

[1]. Press the "SET" button until the light comes on (2 s).
The
indicator light fl ashes.
[2]. Control the motor using the "+" or "-" buttons so that the transmission system runner moves to link up with the trolley and closes the door.
Pressing and holding the "
-" button closes the door.
Release the "-" button before the motor has time to force against the door.
Pressing and holding the "
+" button opens the door.
[3]. Adjust the closed position using the "+" or "-" buttons.
Release the "-" button before the motor has time to force against the door.
[4]. Press "SET" to validate the closed end limit and start the self-learning cycle.
The door runs through a complete Open Close cycle and the
If the self-learning cycle was completed correctly, the
If the self-learning cycle was not completed correctly, the
During self-learning:
When the door is moving, pressing any button will stop the movement and stop the self-learning mode.
When the door is stopped, pressing "SET" until the light comes on and the
The self-learning mode can be called up at any time even after the self-learning cycle has been completed.

Memorising remote controls

Up to 32 control channels can be stored.
Running this procedure for a previously stored channel will clear it.
At this stage in the installation process, the Dexxo Optimo RTS motor drive unit is ready to run.
PROG
P0
P1
Fig.
15
indicator light goes out.
indicator light stays on.
indicator light continues to fl ash.
Fig.
16
. Press for 2 s: memorise remote controls
. Press for 7 s: delete remote controls
. Press for 0.5 s: call up and exit the setup menu
. Press for 2 s: start self-learning
. Press for 7 s: clear self-learning and settings
. Stop self-learning
. Modifying a setting value
. Using the forced mode
. Operation indicator light (red)
. End limit setting and self-learning indicator light (green)
. P0 - P1 parameters indicator (green)
indicator light comes off (2 s) will exit the self-learning mode.