MAINTENANCE
Replacing the bulb in the light unit (Fig. 12)
[1] [2]. Remove the light cover.
[3] [4]. Unscrew and replace the defective light bulb.
[5] [6] [7]. Refit the light cover.
Use a 230 V 40 W E27 socket light bulb.
Checking
The obstacle detection function
Every six months, check that the door reverses direction when an obstacle prevents the door from closing (at least 50 mm above floor level).
The safety mechanisms (cells, pedestrian door contact)
Check correct operation every six months (refer to page 4).
The back-up battery
To ensure optimum battery life, we recommend that the power to the motor is switched off and the door is operated for a number of cycles using
battery power (three times a year).
TECHNICAL SPECIFICATIONS
Basic technical specifications
Mains power supply
Power consumption on standby
Max. power consumption
Traction force – Peak force
Use
Number of channels that can be memorised
Somfy radio frequency
Integrated light
Operating temperature
6
12
230 V - 50 Hz
20 cycles per day with a standard rail (tested for 36,500 cycles)
433,42 MHz RTS
230 V / 40 W max. E27 socket
-20 °C / +60 °C
4 W
120 W
800 N
32