Installation Place
• A place which provides the spaces around the indoor unit as shown in the
diagram
• A place where there are no obstacles near the air inlet and outlet
• A place which allows easy installation of the piping to the outdoor unit
• A place which allows the front panel to be opened
• The indoor unit shall be installed at least 2.5 m height. Also, it must be
avoided to put anything on the top of the indoor unit.
CAUTION
• Direct sunlight to the indoor unit's wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner's manual.)
Remote control
• A place where there are no obstacles such as a curtain that may block the
signal from the indoor unit
• Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment. (This is necessary to prevent image disturbances or
noise interference.)
• The location of the remote control should be determined as shown below.
(Side view)
Remote
Reception
control
range
Cutting a Hole and Mounting
Installation Plate
Cutting a hole
When installing the refrigerant pipes from the rear
The center of the pipe hole
is above the arrow.
1. After determining the pipe hole position on the mounting plate (
the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire lath or metal plate, be sure
to use a pipe hole brim ring sold separately.
Mounting the installation plate
Hook
Pipe hole
Indoor unit
INDOOR UNIT
INDOOR UNIT
(Top view)
Indoor unit
Remote
control
Pipe hole
Ø65 mm
120 mm
65
Hook
Installation
Hook
plate
Thread
Pipe hole
Weight
5
Mounting screw
When the installation plate is directly mounted
on the wall
1. Securely fi t the installation plate onto the wall by screwing it in the upper and
lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use the
anchor bolt holes as illustrated in the below fi gure.
3. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with a mounting screw, do not use the
anchor bolt holes. Otherwise, the unit may fall down and result in personal
injury and property damage.
Installation plate
(Keep horizontal direction.)
5 mm dia. hole
CAUTION
Failure to fi rmly install the unit may result in personal injury and property
damage if the unit falls.
• In case of block, brick, concrete or similar type walls, make 5 mm dia. holes
in the wall.
• Insert clip anchors for appropriate mounting screws 5.
NOTE
• Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
Piping and Drain Hose Installation
Piping and drain hose forming
* Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Æ
), drill
Left
Bottom right
Right
1. Die-cutting back body slit
Cut out the slit on the left or right side of the back body for the left or right
connection and the slit on the bottom left or right side of the back body
103
for the bottom left or right connection with a pair of nippers.
2. Changing drain hose
For leftward connection, bottom-leftward connection and rearleftward
connection's piping, it is necessary to change the drain hose and drain
cap.
1
4
5
Mounting screw
Ø4 x 25R
Clip anchor
(local parts)
Anchor bolt
Projection
15 mm or less