EGSP/EGSK
If the motor turns in the wrong direction:
Note
When the motor is removed (e.g. turning the
motor) the reference position is lost.
S Start a reference run as detailed in the
chapter 6 Commissioning", in order to
reference the new positioning cycle.
8

Service and maintenance

Warning
Controller signals can cause the EGSP/EGSK to make unintentional move
ments.
S Switch off the controller before performing any work on the EGSP/EGSK
and secure the controller against unintended restart.
On cleaning and maintenance:
If necessary, clean the exterior of the EGSP/EGSK with a soft cloth.
S
Cleaning agents: any gentle agent.
Grease the recirculating ball bearing spindle and bearings guide in accordance
S
with the stated running performance or at all lubricating points, every 6
months at the latest (grease è chapter 10 Accessories").
For that purpose, there are lubrication holes aB or grease nipples aC available: