Putting Out Of Operation For A Longer Period (Storage) En; Maintenance And Cleaning - Abicor Binzel FES-200 W3 Manual De Instrucciones

Ocultar thumbs Ver también para FES-200 W3:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

9 Maintenance and cleaning

8.1 Putting out of operation for a longer period (storage)
1 Switch off the fume extraction system by turning the rocker switch (2) (0 position).
2 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled down in the
fume extraction system.
3 Dedust the filter
 5.2 Filter dedusting (dedusting by rotation) on page EN-13
4 Empty the dust collecting drawer
 5.1 Emptying the dust collecting drawer on page EN-12
NOTICE
• The fume extraction system must not be cleaned by means of a water jet.
5 Clean the dust collecting drawer using a damp disposable cloth or an appropriate industrial vacuum cleaner.
6 Clean the outside of the fume extraction system using a damp disposable cloth.
7 Dispose of the dust collecting bag and the disposable cloths according to the local regulations.
 12 Disposal on page EN-24
9 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Disconnect all electrical connections.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Before performing any maintenance and cleaning work, suitable safety measures must be taken.
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with locally filtered
forced ventilation.
• Only qualified personnel are permitted to perform work on the device or system.
• Check and wear your personal protective equipment.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask Class P3, protective
gloves and safety shoes.
EN - 20
FES-200 W3
BAL.0335.0 • 2019-08-16
Tabla de contenido
loading

Productos relacionados para Abicor Binzel FES-200 W3

Tabla de contenido