KENMORE ELITE 110.8772 Serie Manual De Uso Y Cuidado página 21

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Now Auto Dry works
SmartHeat
TM
improves drying performance with Auto Moisture
Sensing Plus, which advances the cycle as moisture is extracted
from clothing. A thermistor (electronic temperature sensor) and
moisture sensing strips in the dryer drum help measure the
amount of moisture in the clothes as they tumble. An electronic
control determines the load type to help save time, avoid
overdrying, and increase the accuracy of the end dryness level.
After the first 5 minutes of an automatic cycle, the estimated time
display will adjust based on the approximate
load size, cycle,
dryness level selected and amount of moisture left in the clothes.
When the clothes have reached approximately
80% of the
dryness level selected, the estimated time display will adjust
again, showing the final drying time. Auto Moisture Sensing Plus
takes the guesswork out of drying time and enhances fabric care.
To use a Timed Cycle
NOTE: A light next to each feature will glow green when the
feature is selected or will glow amber when the feature is
selectable.
Press a Timed Cycles button.
Press MORE TIME or LESS TIME until the desired drying
time is displayed. Tap MORE TIME or LESS TIME, and the
time will change by 1-minute intervals. Press and hold
MORE TIME or LESS TIME, and the time will change by
5-minute intervals.
NOTE: The More Time and Less Time buttons can be
used only with Timed Cycles and the Touch Up Cycle.
i
÷}
]med
............
Cycle
Press TEMPERATURE until the desired temperature
glows.
NOTE: During a Timed Cycle, you can change the settings for
Time, Temperature, WRINKLE GUARD ® and End of Cycle
Signal. Press STOP twice to stop the dryer and clear the
settings. Select another cycle or option.
To use a SteamCare
Cycle
NOTE: A light next to each feature will glow blue when the
feature is selected or will glow amber when the feature is
selectable.
Use of a fabric softener sheet is not recommended
with
SteamCare cycles as it may cause temporary staining on
clothes.
Press the POWER button. Then rotate the dial to select
the SteamCare Cycle. The indicator light for the selected
cycle will glow blue. The preset modifiers for the selected
cycle will glow green. Selectable options will glow amber.
If an option or modifier is unavailable with the selected
cycle, the light will not illuminate. The actual cycle time (in
minutes) will show in the display.
Press MORE TIME or LESS TIME until the desired drying
time is displayed. Tap MORE TIME or LESS TIME, and the
time will change by 1-minute intervals. Press and hold
MORE TIME or LESS TIME, and the time will change by
5-minute intervals.
NOTE: The More Time and Less Time buttons can be
used only with Timed Cycles and the Touch Up Cycle.
T+med
Cycle
Adjust
Press TEMPERATURE until the desired temperature
glows.
NOTE: During the Touch Up Cycle, you can change the
settings for Time, Temperature, WRINKLE GUARD ®and End
of Cycle Signal. During the Refresh Cycle you can change
WRINKLE GUARD ®and the End of Cycle Signal. Press STOP
twice to stop the dryer and clear the settings. Select another
cycle or option.
4. (OPTIONAL STEP) If desired, select OPTIONS. For more
details, see "Options."
5. (OPTIONAL STEP) If desired, set the End of Cycle Signal.
Select LOUD or SOFT by pressing the Cycle Signal button to
alert you when a cycle ends.
6. Press and hold START for approximately
3 seconds until
dryer starts. Be sure the door is closed.
If you do not press START within 5 minutes of selecting
the cycle, the dryer automatically shuts off.
If you wish to end your drying cycle after pressing Start,
press STOP twice.
To stop your dryer at any time
Press STOP twice or open the door.
To pause the dryer at any time
Open the door or press STOP once.
To restart the dryer
Close the door. Press and hold START until dryer starts.
NOTE: Drying will continue from where the cycle was interrupted
if you close the door and press Start within 5 minutes. If the cycle
is interrupted for more than 5 minutes, the dryer will shut off.
Select new cycle settings before restarting the dryer.
bol
t_ol Look
%d
This feature allows you to lock your settings to avoid unintended
use of the dryer. You can also use the Control Locked feature to
avoid unintended cycle or option changes during dryer operation.
To enable the Control Locked feature:
Press and hold CYCLE SIGNAL for 3 seconds. The Control
Locked indicator light glows, and a single beep tone is heard. To
unlock, press and hold CYCLE SIGNAL for 3 seconds. The
indicator light turns off.
Select the correct cycle and dryness level or temperature for your
load. If an Auto Cycle is running, the display shows the estimated
cycle time, which is determined by your dryer automatically
sensing the dryness level of your load. If a Timed Cycle or
SteamCare Cycle is running, the display shows the exact number
of minutes remaining in the cycle.
Cool Down tumbles the load without heat during the last few
minutes of all cycles. Cool Down makes the loads easier to
handle and reduces wrinkling. The length of the Cool Down
depends on the load size and dryness level.
Drying tips
Follow care label directions when they are available.
If desired, add a fabric softener sheet. Follow package
instructions.
To reduce wrinkling, remove the load from the dryer as soon
as tumbling stops. This is especially important for permanent
press, knits and synthetic fabrics.
21

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido