I-3 Radiant Heater
10. Check for gas leaks and proper function upon
installation, before building repopulation and
when relocating.
11. If the gas flow is interrupted and the burner flame
is extinguished, immediately shut off the gas. Do
not relight the brood heater until you are sure
that all of the gas that may have accumulated
through the brood heater has cleared away. Do
not relight the brood heater until at least five
minutes have passed.
12. If the brood heater is to be relocated, make sure
that all gas connections are capped and the gas
supply is shut off. All connection points must
be leak checked after disconnection and after
reconnection.
WARNING
Burn Hazard
■ The brood heater's emitter and canopy are
extremely hot during operation and shortly after
shutting down.
■ Always be aware of your proximity to the brood
heater and avoid contact with its hot surfaces
during or shortly after operation.
■ Failure to follow this warning can result in burns
leading to severe personal injury.
13. The grower shall inspect the brood heater before
building repopulation. Such inspection should
consist of, but is not limited to, the following
points of action:
-- Insure proper clearance of brood heater to nearest
combustible materials.
-- Check for general cleanliness. Clean if necessary.
-- Check for tightness of the gas hose connections.
14. A qualified service person shall inspect the brood
heater and its gas train at least on an annual
basis. This should consist of, but is not limited to,
the following points of action:
-- Start-up and shut down of the brood heaters
-- Leak check of all pipe joints and hose
connections.
Owner's Manual • I-3
-- Thorough cleaning of the interior and exterior of
the brood heater, its burner assembly, and emitter.
-- Thorough inspection of the brood heater's compo-
nent parts for corrosion, stripped threads, etc. with
subsequent parts replacement as necessary.
-- Gas pressure checks.
15. Turn off the gas supply when the brood heater
is not in use.