Note: The snooze can be set for 0 to 30 minutes in 5-minute increments.
If 0 minutes is selected pressing the WIND/RAIN/SNZ button will
deactivate the alarm and it will not come back on.
6. Press and release the SET button to confirm and advance to the
temperature format setting.
XI. SELECTING ˚F OR ˚C
TIME
WWVB
MOON
DATE
1. Press and hold the SET button for 5 seconds.
2. "LCD" will show in the time LCD and the number setting will flash.
3. Press and release the SET button eleven times.
4. Either "˚F" or "˚C" will flash in the TIME LCD.
5. Press and release the ALM/+ button to select the temperature
format.
6. Press and release the SET button to confirm and advance to the
rainfall unit setting.
XII.SETTING THE UNIT OF RAINFALL (inch/ mm)
WIND
mph
RAIN
1. Press and hold the SET button for 5 seconds.
2. "LCD" will show in the time LCD and the number setting will flash.
3. Press and release the SET button twelve times.
4. Either "inch" or "mm" will flash in the TIME LCD (bottom right corner)
5. Press and release the ALM/+ button to select the desired rainfall
unit.
6. Press and release the SET button to confirm and advance to the
forecast sensitivity setting.
P.13
GB
FEATURES OF THE WS-9046U
WWVB Tower
Icon (indicates
TIME
WWVB
time reception)
MOON
DATE
Current moon
phase display
INDOOR
Comfor t Level
Indicator
FORECAST
Weather
Tendency Arrow
OUTDOOR
WIND
mph
Wind Speed in
mph
I. WEATHER FORECAST
The weather forecasting feature is estimated to be 75% accurate and
is for the next 12 to 24 hours. The weather forecast is based solely
upon the change of air pressure over time. The WS-9046U averages
past air-pressure readings to provide an accurate forecast-creating a
necessity to disregard all weather forecasting for 12-24 hours after the
unit has been set-up, reset, or moved from one altitude to another (i.e.
from one floor of a building to another floor). In areas where the weather
P.15
GB
XIII.SETTING THE FORECAST SENSITIVITY
Note: The forecast sensitivity can be adjusted to allow for areas that
have a higher or lower sensitivity to changing air pressure (for example
coastal areas have more pressure change than areas such as southern
Arizona).
The numbers correspond to the amount of air pressure change
necessary to trigger a change in the forecast icon. Areas that tend to
have more air pressure change would set the sensitivity to 3, while
areas that experience lower than normal air pressure change would
set the sensitivity to 1.
bft
TOTAL
1. Press and hold the SET button for 5 seconds.
inch
2. "LCD" will show in the TIME LCD and the number setting will flash.
3. Press and release the SET button twelve times.
4. Either "1", "2" or "3" will flash in the TIME LCD and the forecast icon
5. Press and release the ALM/+ button to select the forecast sensitivity
6. Press and release the SET button to confirm the forecast sensitivity
is not largely affected by the change of air pressure, the sensitivity
setting should be set to 1. In areas where the air pressure changes
more rapidly (such as coastal areas) the sensitivity setting should be
Radio-
set to 3.
controlled time
icon (indicates
A. WEATHER ICONS
radio-controlled
There are 3 possible weather icons that will be displayed in the
time turned on)
FORECAST LCD:
TENDENCY
Alarm icon
HUMIDITY
Sunny-indicates that the weather is expected to improve (not that the
%
weather will be sunny).
Sun with Clouds-indicates that the weather is expected to be fair (not
RH
that the weather will be sunny with clouds).
Clouds with Rain-indicates that the weather is expected to get worse
(not that the weather will be rainy).
Forecast icon
These icons indicate the expected weather change in the next 12 to
Satellite icon
24 hours. The icon does not give an exact prediction of the weather,
(indicates
however it should be viewed as a generalization of the expected weather
outdoor
change (for example a "sunny" icon indicates the weather is expected
HUMIDITY
transmission)
%
to improve).
RH
The weather icons change when the unit detects a change in air
Beaufort Scale
pressure. The icons change in order, from "sunny" to "partly sunny" to
bft
Wind Indicator
"cloudy" or the reverse. It will not change from "sunny" directly to "rainy",
GUST
although it is possible for the change to occur quickly. If the symbols
Gust/Wind
do not change then the weather has not changed, or the change has
Chill/Rainfall
been slow and gradual.
icon
B. WEATHER TENDENCY ARROWS
Other possible displays in the FORECAST LCD are 2 weather tendency
arrows, one that points up (on the left side of the LCD) and one that
points down (on the right side of the LCD). These arrows reflect current
changes in the air pressure. An arrow pointing up indicates that the air
pressure is increasing and the weather is expected to improve or remain
good, an arrow pointing down indicates that the air pressure is
decreasing and the weather is expected to become worse or remain
poor. No arrow means the pressure is stable.
TIME
WWVB
MOON
DATE
INDOOR
FORECAST
and tendency arrows will flash in the FORECAST LCD.
and complete the programming.
TENDENCY
HUMIDITY
%
RH
P.14
GB
TENDENCY
P.16
GB
loading