Genius JA388 Instrucciones Para El Uso página 7

Equipo electrónico para portones de tipo batiente 115v
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5. MICROSWITCH PROGRAMMING
LEAF 1 FORCE
1 (MIN)
2
3
4
5
6
7
8 (MAX)
DS1
LOGIC
PAUSE (s)
E
EP
B
C
A
A
10
A
20
A
30
A
60
A
120
SP
SP
10
SP
20
SP
30
SP
60
Fig. 18
SP
120
The equipment is endowed with two groups of microswitches -
DS1 (fig. 18) and DS2 (fig.19) - which make it possible to program
the gate operation parameters.
5.1. MICROSWITCHES DS1 (fig. 18)
Leaf 1 and 2 force
By using microswitches SW1, SW2 and SW3, the force (and thus
anti-crushing safety) of the operator connected to leaf 1 can be
programmed. The same operation has to be repeated on the
motor connected to leaf 2, by using microswitches SW4, SW5 and
SW6.
Function logic
The automated system's function logic can be selected with
microswitches SW7, SW8, SW9 and SW10. By selecting an automatic
logic (A, SP), the combination of microswitches enables selection
of pause time too (waiting time, in opening position, before
automatic re-closing).
The available logics - their operation is described in tables 3/a-
b-c-d-e-f, are as follows: A - SP (Automatic), E - EP - B (Semi-
automatic), C (Dead-man).
Closing leaf delay
Programming of microswitches SW11 and SW12 enables delay of
the closing start of leaf 1 with respect to leaf 2, in order to avoid
the leaves overlapping during movement, and thus increase the
safety of the system.
5.2. MICROSWITCHES DS2 (fig. 19)
Opening leaf delay
Programming of microswitch SW1 enables delay of the opening
start of leaf 2 with respect to leaf 1, in order to avoid the leaves
obstructing each other during the initial stage of movement.
Closing photocells logic
By using microswitch SW2, you can select the type of behaviour
of the automated system if the photocells protecting the gate
closing movement are engaged. You can obtain either immediate
reversing of the leaves or a stop followed by reversing when the
photocells are disengaged.
LEAF 2 FORCE
SW1
SW2
SW3
ON
ON
ON
1 (MIN)
OFF
ON
ON
2
ON
OFF
ON
3
4
OFF
OFF
ON
ON
ON
OFF
5
OFF
ON
OFF
6
ON
OFF
OFF
7
OFF
OFF
OFF
8 (MAX)
1
2
3
4
5
SW7
SW8
SW9
SW10
ON
/
ON
ON
ON
/
OFF
ON
ON
ON
/
ON
OFF
ON
ON
/
OFF
OFF
ON
ON
0
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
0
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW4
SW5
SW6
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
7
8
9
10 11 12
CLOSING LEAF
SW11
SW12
DELAY (s)
20
ON
ON
10
OFF
ON
5
ON
OFF
0
OFF
OFF
Fail safe
Programming the microswitch SW3 makes it possible to activate
or de-activate the photocells control test. When Fail safe is active,
the equipment checks the photocells before every opening or
closing movement.
Reversing stroke + over-pushing stroke
By using the microswitch SW4, you can activate the "reversing
stroke" and the "over-pushing stroke". The "reversing stroke" pushes
the leaves to close for a few moments before opening the gate,
thus facilitating release of the electric lock. The "over-pushing
stroke" commands a closing thrust at full force when the gate has
already reached its stop limit, thus facilitating the locking of the
electric lock.
6. START-UP
6.1. LED CHECK
The table below shows the status of the LEDs in relation to to the
status of the inputs.
Note the following:
Check the state of the LEDs as per Table.
Operation of the status signalling LEDs
LEDs
OP_A
OP_B
STOP
FSWCL
FSWOP
FCA1 (if used)
FCC1 (if used)
FCC2 (if used)
FCA2 (if used)
NB.: The status of the LEDs while the gate is at rest are shown in
bold.
Furthermore, the DL10 LED is on the board and functions as
detailed in the following table:
Gate closed at rest:
OFF
5
OPENING LEAF DELAY (s)
2
0
CLOSING PHOTOCELL LOGIC
REVERSES ON RELEASE
REVERSES IMMEDIATELY
1
2
3
FAIL SAFE
YES
NO
REVERSING STROKE
+ OVER-PUSHING STROKE
YES
NO
L
= closed contact
ED LIGHTED
L
= open contact
ED OFF
LIGHTED
Command activated
Comando inattivo
Command activated
Comando inattivo
Command inactive
Command activated
Safety devices disengaged
Safety devices engaged
Safety devices disengaged
Safety devices engaged
Limit-switch free
Limit-switch engaged
Limit-switch free
Limit-switch engaged
Limit-switch free
Limit-switch engaged
Limit-switch free
Limit-switch engaged
DL10
Gate moving or on
pause:
like indicator-light
ENGLISH
SW1
ON
OFF
SW2
ON
OFF
DS2
4
SW3
ON
OFF
SW4
ON
OFF
Fig. 19
OFF
Time learning:
flashes rapidly