Enlaces rápidos

LYNX 03
LYNX 04
ISTRUZIONI PER L'USO - NORME DI INSTALLAZIONE
INSTRUCTIONS FOR USE - DIRECTIONS FOR INSTALLATION
INSTRUCTIONS - REGLES D'INSTALLATION
INSTRUCCIONES PARA EL USO - NORMAS PARA LA INSTALACION
GEBRAUCHSANLEITUNG - ANWEISUNGEN ZUR INSTALLATION
GEBRUIKSAANWIJZINGEN – INSTALLATIEVOORSCHRIFTEN
24V / 230V
24V / 115V
Tabla de contenido
loading

Resumen de contenidos para Genius LYNX 03

  • Página 1 LYNX 03 24V / 230V LYNX 04 24V / 115V ISTRUZIONI PER L’USO - NORME DI INSTALLAZIONE INSTRUCTIONS FOR USE - DIRECTIONS FOR INSTALLATION INSTRUCTIONS - REGLES D’INSTALLATION INSTRUCCIONES PARA EL USO - NORMAS PARA LA INSTALACION GEBRAUCHSANLEITUNG - ANWEISUNGEN ZUR INSTALLATION...
  • Página 2 22) Interdire aux enfants ou aux tiers de stationner près du produit durant le 6) GENIUS declines all liability caused by improper use or use other than that for fonctionnement.
  • Página 3: Tabla De Contenido

    Control unit mod. LYNX 03 - LYNX 04 • conforms to the essential safety requirements of the following EEC directives: 73/23/EEC and subsequent amendment 93/68/EEC. 89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC Additional information: This product underwent a test in a typical uniform configuration (all products manufactured by GENIUS S.p.A.). Grassobbio, 25-01-2007 Managing Director D. Gianantoni Notes on reading the instruction Read this installation manual to the full before you begin installing the product.
  • Página 4: General Characteristics

    CONTROL BOARD FOR BARRIERS 24 Vdc OPERATING INSTRUCTIONS – INSTALLATION INSTRUCTIONS 1. GENERAL CHARACTERISTICS Thank to its high powered microprocessor, this control unit for 24 Vdc automatic barriers, offers a wide range of functions and adjustments, including deceleration and motor control. A sophisticated electronic control monitors the power circuit at all times and disables the control unit in the event of malfunctions that could impair efficiency of the electronic clutch.
  • Página 5: Connections And Operation

    4. CONNECTIONS AND OPERATION 4.1 TERMINAL BOARD M1 4.1.1 24V power supply Terminals “1-2”. This is the input to which the secondary winding of the transformer, powered at 24 V~ 50/60 Hz, should be connected. When power is supplied by the transformer, this is signalled by the POWER LED lighting up. 4.1.2 B atteries Terminals “3-4”.
  • Página 6: Fitting A Remote Control Receiver Card

    4.3.2 S tart Terminals “17-21”. The status of this input is signalled by the START LED. Any device (e.g. push-button, radio control, etc.) can be connected to this circuit. By closing a contact, the circuit generates a pulse for total opening and/or closing of gate.
  • Página 7: Programming

    7. PROGRAMMING Programming must be done while the control unit is powered off the mains, through the transformer. Programming is not possible by using the buffer batteries only. This ensures that all times and functions of the control unit are correctly programmed.
  • Página 8: Function Logics And Settings

    10. FUNCTION LOGICS AND SETTINGS Dip-switch Function SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Electronic clutch Maximum force, minimum sensitivity Minimum force, maximum sensitivity Automatic closing Deceleration on opening limit-switch ON, from limit-switch forward OFF, immediate stop at limit-switch Condo operation Not accepting START on opening and pause START command operation...
  • Página 9 HINWEISE FÜR DEN INSTALLATIONSTECHNIKER 9) GENIUS is niet aansprakelijk als de regels der goede techniek niet in acht genomen zijn bij de bouw van het sluitwerk dat gemotoriseerd moet worden, noch voor ALLGEMEINE SICHERHEITSVORSCHRIFTEN vervormingen die zouden kunnen ontstaan bij het gebruik.
  • Página 10 Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. GENIUS se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à...

Este manual también es adecuado para:

Lynx 04

Tabla de contenido