1.
WARNINGS
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker
(Residual Current Device) with adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the J3
connector of the equipment (see fig.2).
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).
2.
TECHNICAL SPECIFICATIONS
Power supply
Absorbed power
Motor max. load
Accessories max. load
Electric lock max. load
Operating ambient temperature
Protection fuses
Function logics Automatic / Semi-automatic / "Stepped" safety devices /
Semi-automatic B / Dead-man C / "Stepped" semi-automatic
Opening/closing time
Pause time
Closing leaf delay
Opening leaf delay
Thrust force
Dip-switch adjustable on 8 levels for each motor
Terminal board inputs
Opening safety devices / Closing safety devices / Power supply + Earth
Terminal board outputs
Flashing lamp - Motors - 24 Vdc accessories power
supply- 24 Vdc indicator-light - Fail safe - 12 Vac electric
lock power supply
Rapid connector
Selectable functions
Opening and closing leaf delay - Reversing stroke -
Fail safe - Closing safety devices logic - Pre-flashing
Programming key
4.
ELECTRIC CONNECTIONS
J3
1
2
PE N
L
OP
COM
M1
MAIN
C1
M1
230 VAC
50 Hz
NB.: Capacitors are supplied with the operators.
CONTROL BOARD JA388
115 V~ ( +6% -10%) - 50 Hz
10 W
1200 W
0,5 A
15 VA
-20 °C +55 °C
2 (see fig. 1)
Programmable (from 0 to 120 s)
0, 10, 20, 30, 60, 120 s
0, 5, 10, 20 s
2 s (Can be disabled with the dip-switch)
Open / Open free leaf / Stop / Limit-switch
Rapid connector 5 pins
Logics and pause times - Thrust force -
Simple or Advanced work time learning,
with or without Limit-switch and/or encoder
J4
3
4
5
6
7
8
OP
CL
COM
LAMP
M2
C2
230 VAC
M2
max.60W
TOTALLY OPEN
OPEN LEAF 1
3.
LAYOUT AND COMPONENTS
F1
F1
J3
J3
1
2
PE N
L
OP
COM
COM
MAIN
M1
Led OP_A
TOTALLY OPEN LED
Led OP_B
LED: OPEN LEAF 1 / CLOSE
Led STOP
LED STOP
Led FSWCL LED: CLOSING SAFETY DEVICES
Led FSWOP LED: OPENING SAFETY DEVICES
Led FCA1
LED: LEAF 1 OPENING LIMIT-SWITCH
Led FCC1
LED: LEAF 1 CLOSING LIMIT-SWITCH
Led FCA2
LED: LEAF 2 OPENING LIMIT-SWITCH
Led FCC2
LED: LEAF 2 CLOSING LIMIT-SWITCH
DL10
LED: TIME LEARNING SIGNALLING
J1
LOW VOLTAGE TERMINAL BOARD
J2
RAPID CONNECTOR 5 PINS
J3
230 VAC POWER SUPPLY TERMINAL BOARD
J4
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
J5
INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BOARD
J6
LIMIT-SWITCH AND ENCODER TERMINAL BOARD
F1
MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 5A)
F2
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F
TIME LEARNING SELECTION PUSH-BUTTON
DS1
1ST GROUP OF MICROSWITCH PROGRAMMING
DS2
2ND GROUP OF MICROSWITCH PROGRAMMING
J1
9 10 11 12 13 14 15 16 17 18 19
A
B
CL OP
-
STP
FSW
OPEN
For connection of
the photocells
devices, see
STOP
paragraph 4.1.
1
F2
F2
OP_A
STOP
FSWCL
J1
J4
J4
J1
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19
OP
A
B
CL OP
STP
-
CL
LAMP
M2
OPEN
FSW
J6
J5
20 21
+
+
-TX
LOCK
-
-
+24V
FSW
W.L.
24 Vdc
3 W
12 V ac
and safety
ENGLISH
DS2
DS1
1 2
3 4
5
6 7 8
9 10 11 12
1 2 3 4
J2
J2
F
F
DL10
DL10
FCC1
FCC2
OP_B
Led
FSWOP
FCA1
FCA2
J6
J6
J5
J5
22
24 25
23
20 21
+
+
LOCK
-TX
-
-
+24V
FSW
W.L.
Fig. 1
22
23
24 25
LIMIT-SWITCH