English
〈 WR12DAF2 〉
kgf
cm
N
m
•
•
M8 × 30
1000
100
High tension
bolt
800
80
600
60
400
40
Ordinary bolt
200
20
0
0
0
1
Tightening time: sec.
(Steel plate thickness
t = 10 mm)
Bolt
Nut
〈WR12DAF2〉
11
kgf
cm
N
m
•
•
1200
120
1000
100
800
80
600
60
400
40
200
20
0
0
2
3
Tightening time: sec.
(Steel plate thickness
t = 10 mm)
Steel plate thickness t
M12 × 45 High tension bolt
(tighening time 3 sec)
kgf
cm
N
m
•
•
1600
160
1200
120
When full recharged
800
80
When completely
400
40
discharged
0
0
0
20
Number of tightenings (PCS)/charging
kgf
M10 × 30
High tension
bolt
Ordinary bolt
0
1
2
3
Fig. 19
*The following bolt is used.
Ordinary bolt: Strength grade 4.8
High tension bolt: Strength grade 12.9
(
Explanation of strength grade:
4 — Yield point of bolt: 32 kgf/mm
8 — Pulling strength of bolt: 40 kgf/mm
Fig. 20
a
40
60
80
100
Fig. 21
cm
N
m
•
•
M12 × 45
1400
140
High tension
bolt
1200
120
1000
100
800
80
600
60
Ordinary bolt
400
40
200
20
0
0
0
1
2
Tightening time: sec.
(Steel plate thickness
t = 25 mm)
3
)
2
2