The Installation Space; Dimensions And Clearances - Monogram FZIR360NNRH Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Design Guide - Standard Installation

THE INSTALLATION SPACE

Water And Electrical Locations
Electrical and water supply must be located as
shown.
The Cutout Depth Must Be 24" (60.96 cm)
Minimum
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit:
When installed beneath a soffit, the soffit cannot
exceed the 24" (60.96 cm) installation depth shown.
The top case trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
• Water line can enter the opening through the floor
or back wall. The water line should be 1/4" O.D.
copper tubing or QuickConnect
cold water line and water connection location,
long enough to extend to the front of the unit.
Installation of an easily accessible shut-off valve in
the water line is required.
31-1000416 Rev. 0
kit between the
7

DIMENSIONS AND CLEARANCES

35"
Case Width
25-3/8" Case Depth
*84" From
*83-1/2"
Floor to
at
Top Frame
Rear
36" Frame to
Frame Width
Depth Including
3/4" Panel 25-15/16"
Product Clearances
These units are equipped with a 3-position door
stop. The factory set 115° door swing can be adjust-
ed to 90° if clearance to adjacent cabinets or walls
is restricted. Order WX14X99 door stop for precise
settings between 90° and 130°.
23-7/8 "
Minimum
to Wall
130° Door Swing
130°
16-7/8" Min.
115° Door Swing
to Wall
115°
Allow 23-7/8" (60.64 cm) minimum clearance for
a full 130° door swing. Allow 15" (38.1cm) for pan
removal.
For a 90° door swing, allow 4-9/16" min. (11.59 cm)
minimum clearance to a wall. If the 90° doorstop
position is used, pan access is maintained but pan
removal is restricted.
See illustration on page 12 to determine door swing
interaction with adjacent cabinets or countertops.
* Shipping height. The
product can be adjusted
to fit into a cutout that
is 84-1/2" (214.63 cm)
max. height. Note that
the top case trim at the
front is 1/2" (1.27 cm)
higher and will overlap
upper cabinetry or soffit.
Use leveling legs and
wheels for a maximum
1" (2.54 cm) height
adjustment.
"
4-9/16
Min. Distance to Wall
"
23-5/8
90º Door Swing
Case
Behind
Frame
"
36-1/2
90°
Tabla de contenido
loading

Tabla de contenido