1
2
TERMINAL BOARDS
CL.RES
M/S
Bus end resistance jumper:
CL.RES
CL.RES
XDV/304
1
2
INSTALLATION
Remove the unit from the metal support by sliding it after pressing the plastic button (figure 1).
Fasten the metal support to the round built-in box of Ø 60 mm (figure 2) or to the rectangular box 503
(figure 3-4) using the provided screws and observing the UP indication .
The box must be fitted at a suitable height in relation to the installer.
Avoid excessive tightening of the screws.
Once the connections have been made, attach the video terminal to the metal support (figure 5-6).
To release the unit from the metal support, press the plastic hook and lift the terminal (figure 7).
1
2
5
CL.RES
Chessboard
monitor
3
3
6
TECHNICAL FEATURES
Power supply from BUS: 15-20 VDC
Absorption: 200 mA max (<1 mA stand-by)
Single LED absorption (panic, Ring disa-
bled): 1 mA
Dimensions: 170x145x30.9 mm
Storage temperature: -25 °C +70 °C
Operating temperature: 0 °C +35 °C
IP degree: IP 20
Standard video: PAL/NTSC
Display: LCD TFT colour 3.5"
Alarm input (
AL
–
Doorbell
+
BUS line input (not polarised)
B
(
) Function only accessible if the system featu-
1
res 1 porter station
Master/slave selection jumper
SLAVE
MASTER
M/S
M/S
Bianca
4
1
2
7
)
1
If multiple monitors
are called in parallel,
they will all ring, but
the video will only be
activated in the re-
ceivers configured as
Masters
3
EN