Parallel Control - Denon Professional DN-501C Manual Del Propietário

Ocultar thumbs Ver también para DN-501C:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Parallel Control

Parallel control has two modes, normal mode and hot start mode.
The MODE 1,2 pins are used to switch this mode.
n Parallel remote mode switching
• Parallel remote mode is switched according to the status of parallel remote inputs #5 and #6.
MODE 1
HIGH
HIGH
MODE 2
HIGH
LOW
FUNCTION
NORMAL
Reserved
Hot Start 1: Hot list #1 - #10 can be played from the parallel remote.
Hot Start 2: Hot list #11 - #20 can be played from the parallel remote.
Hot start is a function that starts playback instantaneously from the preset point.
Hot Start mode can be switched to Hot Cue using "Para Rem Mode" in the "Preset setting".
If the mode is set to the Hot Cue mode, when Hot Start input is performed, playback does not start
immediately and instead switches to the standby state at the start point.
n Hot Start Assignment
If one of the HOT START terminals is shorted when the RELOAD terminal is in the shorted state, the
current track is assigned to the shorted Hot Start number (reload function).
For details on assigning Hot Start, see "Playing back from track hot points (Hot Start playback)"
(vpage 27).
LOW
LOW
HIGH
LOW
HOT START 1
HOT START 2
n About Connections
• Normal Mode
NO.
DN-501C
I/O
NAME
1
-
GND
2
I
PLAY
3
I
PAUSE
4
I
CUE
5
I
MODE 1
6
I
MODE 2
7
I
SEARCH 7
8
I
SEARCH 6
9
I
FADER START
10
-
GND
11
I
SKIP BACK
12
I
Reserved
13
I
Reserved
14
O
PLAY TALLY
15
O
PAUSE TALLY
16
O
CUE TALLY
17
I
Reserved
18
I
Reserved
19
I
Reserved
20
O
STOP TALLY
21
O
EOM TALLY
22
-
TALLY POWER SUPPLY
23
-
GND
24
I
TRACK +
25
I
TRACK –
43
43
• Hot Start Mode / Hot Cue Mode
NO.
DN-501C
I/O
NAME
1
-
GND
2
I
PLAY
3
I
PAUSE
4
I
CUE
5
I
MODE 1
6
I
MODE 2
7
I
RELOAD
8
I
HOT START 1(11)
9
I
HOT START 2(12)
10
-
GND
11
I
HOT START 3(13)
12
I
HOT START 4(14)
13
I
HOT START 5(15)
14
O
PLAY TALLY
15
O
PAUSE TALLY
16
O
CUE TALLY
17
I
HOT START 6(16)
18
I
HOT START 7(17)
19
I
HOT START 8(18)
20
O
STOP TALLY
21
O
EOM TALLY
22
-
TALLY POWER SUPPLY
23
-
GND
24
I
HOT START 9(19)
25
I
HOT START 10(20)
• In Hot Cue mode, the status switches to standby
for hot start input.
• The () contents indicate the assignment for Hot
Start 2 mode.
Tabla de contenido

Solución de problemas

loading

Tabla de contenido