Fault
SPN
FMI
Code
2353
2791
6
2357
2791
7
2363
1073
4
2365
1112
4
2367
1073
3
2368
1112
3
2372
95
16
2373
1209
3
2374
1209
4
2375
412
3
2376
412
4
2377
647
3
2387
641
7
2398
171
2
2448
111
17
2449
641
13
D 22 68
Diesel Engine Failure-Codes chart
SPN
Lamp
Description
Engine Exhaust
Gas Recirculation
Amber
1 (EGR1) Valve
Control
Engine Exhaust
Gas Recirculation
Amber
1 (EGR1) Valve
Control
Engine
Amber
(Compression)
Brake Output #2
Engine
Amber
(Compression)
Brake Output #3
Engine
Amber
(Compression)
Brake Output #2
Engine
Amber
(Compression)
Brake Output #3
Engine Fuel Filter
Amber
Differential Pressure
Engine Exhaust
Amber
Gas Pressure 1
Engine Exhaust
Amber
Gas Pressure 1
Engine Exhaust
Gas
Amber
Recirculation 1
Temperature
Engine Exhaust
Gas
Amber
Recirculation 1
Temperature
Engine Fan
Amber
Clutch 1 Output
Device Driver
Engine Variable
Geometry
Amber
Turbocharger
Actuator #1
Ambient Air
Amber
Temperature
Amber
Engine Coolant
(Blink-
Level
ing)
Engine Variable
Geometry
Red
Turbocharger
Actuator #1
Cumins Description
EGR Valve Control Circuit - Current above normal or grounded circuit
EGR Valve Control Circuit - Mechanical system not responding or out
of adjustment
Engine Brake Actuator Driver Output
2 Circuit - Voltage below normal, or shorted to low source
Engine Brake Actuator Driver Output
3 Circuit - Voltage below normal, or shorted to low source
Engine Brake Actuator Driver Output
2 Circuit - Voltage above normal, or shorted to high source
Engine Brake Actuator Driver 3
Circuit - Voltage above normal, or shorted to high source
Fuel Filter Differential Pressure -
Data Valid But Above Normal
Operating Range - Moderately Severe
Exhaust Gas Pressure Sensor 1
Circuit - Voltage above normal, or shorted to high source
Exhaust Gas Pressure Sensor 1
Circuit - Voltage below normal, or shorted to low source
Exhaust Gas Recirculation Temperature Sensor Circuit - Voltage
above normal, or shorted to high source
Exhaust Gas Recirculation Temperature Sensor Circuit - Voltage
below normal, or shorted to low source
Fan Control Circuit - Voltage above normal, or shorted to high source
VGT Actuator Driver Circuit (Motor) - Mechanical system not respond-
ing
or out of adjustment
Ambient Air Temperature - Data erratic, intermittent or incorrect
Coolant Level - Data Valid But
Below Normal Operating Range - Least Severe Level
VGT Actuator Controller - Out of
Calibration