Nice ANATEL Guarita IP Instrucciones Y Advertencias Para La Instalación Y El Uso página 132

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

− COM VALIDAÇÃO (With Validation)
When an activation is performed (example: Entrance), the parking space will not be filled
until occur the vehicle pass through sensors (inductive loop or photocell) installed near the
access gate or barrier gate. Therefore, after the pass the parking space will be filled. Without
any pass through two sensors the parking space will be filled.
− COM VALIDAÇÃO+SL (With Validation + "Free Exit")
This option applies the parking space setting With Validation and complements with the
definition of "Saída Livre – Free Exit", that is, the system does not consider the last access
to validate the exit operation. If the system user has entered in a moment that the system
was inactive, or the hitchhiking in the activation of another user, the exit gate or barrier gate
will be activated normally.
− SEM VALIDAÇÃO+SL (Without Validation + "Free Exit"):
This option applies the parking space setting Without Validation and complements with the
definition of "Saída Livre - Free Exit", that is, the system does not consider the last access
to validate the exit operation. If the system user has entered in a moment that the system
was inactive, or the hitchhiking in the activation of another user, the exit gate or barrier gate
will be activated.
− FORMATAR CONTROLE DE REENTRADA (Format Re-entry Control)
The "Formatar - Format" function can be used to reset the parking space counting of each
users, in other words, performing the formatting, all the users will have their parking spaces
released and the counting process will restart from the next access. If the first access be an
entrance access, the user parking space will be considered filled right after the access. If
the first access be an exit access, the system will release the exit and will wait the user
return by entrance access to count the occupation of parking space.
PERFORMING THE FORMATTING RE-ENTRY CONTROL
With the CONTROLE DE VAGAS – PARKING SPACE CONTROL
function enabled, turn the programming key to the right "ON
position", image 9.1.c, and keep it in this position. Disconnect the
Guarita IP's power supply and then reconnect. A screen with the
formatting option will be displayed, image 11.7.a. Press ENTER,
wait the formatting process and turn the programming key off to
return to the operation mode.
PROTOCOLO DE EVENTOS (Event Protocol)
Through the "Prot EVT" menu is possible select the on-line events send protocol by serial
port (RS232 for communication with PC) or TCP/IP secondary. Select "Linear" to send the
events in Linear-HCS standard or "ContID" to send in the "Contact ID" format (Ademco
standard - use the Internal webserver or Linear-HCS Software for more settings).
Image 11.7.a