Emerson EL-O-MATIC EL Serie Guía De Referencia página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

English
2
Identification
2.1
Weather proof execution
*
Actuator must be isolated electronically before any
(dis)assembly is begun.
*
Before mounting or (dis)assembling the actuator
consult the relevant sections of this manual.
TM
WWW.EL-O-MA TIC.COM
TYPE
EL XXXX XXXXX XXXXX
SERIAL No.
XXXXXXXXXXXXXX
Electrical entry dimensions
2.2
ATEX approved execution
WARNING
*
The ATEX flame proof certified EL electric actuator
is a Group II category 2 equipment and intended
for use in areas in which explosive atmospheres
caused by mixtures of air and gases, vapors or
mists are likely to occur.
Therefore the ATEX flame proof certified electric
actuator may be used in (ATEX) classified Zones 1
& 2 (Gases)
2.3
ATEX Installation instructions
1 The cable entry device and the closing elements of
unused apertures must be of a certified flameproof
type, suitable for the conditions of use and correctly
installed.
2 Heat resistant cable and cable glands shall be
used, suitable for temperatures of at least 130°C.
3 When the EL actuator is connected to a separate
source of heating or cooling, such as a heated or
cooled process vessel or pipeline, the temperature
transfer should not cause the actuator to exceed the
specified ambient temperature range (Tamb = -20
°C ... +60 °C).
4 Wiring dimensions for external earth connection is
4mm² (12 AWG), for internal earth connection max.
2.5mm² (22-12AWG)
5 Blind plugs or cable gland shall be engaged into the
cable entries minimal 5 threads.
6 When replacing cover screws, use cover screws
according ISO 3506 with property class A2-70.
4
Actuator size
Power supply specifications
ATEX Reference Guide EL Electric actuators
2.4
Special ATEX conditions for safe use
1 Ambient temperature range: -20° to +60°C
EL 150
Type:
240
U:
V
0.5
I:
A
50
f:
Hz
Cable and cable glands compatible
with a temperature of 130°C
II 2 G Ex db IIB T4
DEKRA 12ATEX0001 X
Serial No.:
Year of manufacturing:
Emerson, 7556BR Hengelo NL
2 Contact Emerson for information with regard to
dimensions of the flame proof joints.
DOC.ATX.EL.1 Rev.: C
February 2012
Actuator size
Power supply
specifications
Ex db Flame
0344
proof version

Hide quick links:

Tabla de contenido
loading

Tabla de contenido