Standard Accessories - Gima CORSIA Manual De Istrucciones

Ocultar thumbs Ver también para CORSIA:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

The CORSIA aerosol is intended for use in the electromagnetic environment specified below.
The customers or the user of the CORSIA aerosol should assure that it's used in such an environment.
Emissions Test
Irradiated / Conducted emissions CISPR11
Irradiated / Conducted emissions CISPR11
Harmonic emissions
IEC/EN 61000-3-2
Voltage fluctuations /
flicker emissions
IEC/EN 61000-3-3
The CORSIA aerosol is intended for use in the electromagnetic environment specified below.
The customers or the user of the CORSIA aerosol should assure that it's used in such an environment.
Immunity Test
Electrostatic discharge (ESD)
IEC/EN 61000-4-2
Electrical fast transient / burst
IEC/EN 61000-4-4
Surge
IEC/EN 61000-4-5
Loss of voltage, brief voltage interruptions
and variations
IEC/EN 61000-4-11
Magnetic field
IEC/EN 61000-4-8
Conducted Immunity
IEC/EN 61000-4-6
Irradiated Conducted
IEC/EN 61000-4-3
Note U
is the value of the power supply voltage
T
For each individual patient it's recommended to use the nebulizer for 6 months or for a maximum of 120 treatments.
The nebulizer must be replaced after a long period of inactivity, if it is deformed or broken, or if the nebulizer nozzle is blocked
by dry medicine, dust, ecc..
Only use the original nebulizer supplied with the device
The air filter must be replaced every 25 hours of functioning or when it result particulary worn.
For replacement, lift the filter and replace with a new one.
Only use original filter
DON'T USE THE DEVICE WITHOUT AIR FILTER
Guidance and manufacturer's declaration – Electromagnetic Emissions
Guidance and manufacturer's declaration – Electromagnetic Emissions
± 2kV power supply
± 1kV differential mode
5%U
40%U
70%U
3Vrms 150kHz to 80MHz
(for appliances that aren't life - supporting)
3V/m 80MHz to 2.5 GHz
(for appliances that aren't life - equipment)

STANDARD ACCESSORIES

ACCESSORIES
(Nebulizer HI-FLO, Adult Mask, Pediatric Mask,
Air Tube and Mouth-piece)
Air Filter (+n°3 spare part)
Compliance
Group 1
Class [B]
Class [A]
Complies
Compliance
± 6kV on contact
± 8kV in air
for 0.5 cycle
T
for 05 cycle
T
for 25 cycle
T
<5%U
T
for 5 sec
3A/m
HI-FLO KIT
13
Electromagnetic environment - guidance
The CORSIA aerosol only used RF energy
only for its internal functioning.
Therefore its RF emissions are very low and
are not cause interference in
proximity of any Electronic appliances.
The CORSIA aerosol can be used in all
environments, including domestic and
those connected directly to the public mains
distribution that supplies power
to environments used for domestic scopes.
Electromagnetic environments - guidance
Floors should be wood, conceret or
ceramic tile. If floors are coverei with
synthetic material, the relative
humidity should be at least 30%.
Mains power quality should be that of a
typical commercial environment or
hospital.
Mains power quality should be that of a
typical commercial environment or
hospital.
Mains power quality should be that of a
typical commercial environment or
hospital If the user of the CORSIA
aerosol request that the appliance
operates continuosly, the use of a
continuity unit is recommended.
The power frequency magnetic field
should be measured in the intended
installation location to assure that it's
sufficiently low.
-
-
Tabla de contenido
loading

Tabla de contenido