Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SOFM: Standard cubic feet per min-
ute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge;
a unit of measure of pressure.
Code Certification:
Products that
bear one or more of the following
marks: UU_, CUL, CULUS, ETL_,
CETL, CETLUS, have been evaluated
by OSHA certified independent safety
laboratories and meet the applicable
Standards for Safety.
*UL_ is a registered trademark of
Underwriters Laboratories and ETL®
is a registered trademark of Electrical
Testing Laboratories.
Cut-In Pressure: While the motor is
off, air tank pressure drops as you
continue to use your accessory. When
the tank pressure drops to a certain
low level the motor will restart auto-
matically. The low pressure at which
the motor automatically restarts is
called "cut-in" pressure.
Cut-Out
Pressure: When an air com-
pressor is turned on and begins to
run, air pressure in the air tank begins
to build. It builds to a certain high
pressure before the motor automati-
cally shuts off, protecting your air tank
from pressure higher than its capacity.
The high pressure at which the motor
shuts off is called "cut-out"
pressure.
Branch Circuit: Circuit carrying elec-
tricity from electrical panel to outlet.
This unit is capable of powering the following accessories. The accessories are
available through the current Power and Hand Tool Catalog or full-line Sears
stores.
Accessories
In Line Filter
Tire Air Chuck
Quick Connector Sets
(various sizes)
Air Pressure Regulators
Oil Fog Lubricators
Air Hose: 1/4", 3/8" or 1/2" I.D. in
various lengths
Refer to the selection chart located on
the unit to select the tools this unit is
capable of powering.
_The
use of any
--
other accessory
not recommended
for use with
this tool could be hazardous.
Use
only accessories
rated equal to
or higher than the rating of the air
compressor.
This air compressor
pump is capable
of running continuously.
However, to
prolong the life of your air compressor,
it is recommended
that a 50%-75%
average duty cycle be maintained;
that is, the air compressor
pump
should not run more than 30-45
minutes in any given hour.
9 - ENG