5
System Set Up
5.4 Indoor unit only operation (during installation work)
In the case when DHW or heating operation is required prior to connection of the
outdoor unit; i.e. during installation work, an electric heater in indoor unit (*1) can be
used.
*1 Model with electric heater only.
1. To start operation
● Check if the indoor unit power supply is OFF, and turn DIP switch 4-4 and 4-5 ON.
● Turn ON the indoor unit power supply.
5.5 Smart grid ready
In DHW or heating operation, the commands in the table below can be used.
IN11
IN12
OFF (open)
OFF (open)
ON (short)
OFF (open)
OFF (open)
ON (short)
ON (short)
ON (short)
en
5.6 Using SD memory card
The cylinder unit is equipped with an SD memory card interface in FTC.
Using an SD memory card can simplify main remote controller settings and can store operating logs. *1
*1 To edit main remote controller settings or to check operating data, an Ecodan service tool (for use with PC) is required.
<Handling precautions>
(1) Use an SD memory card that complies with the SD standards. Check that the
SD memory card has a logo on it of those shown to the right.
(2) SD memory cards to the SD standards include SD, SDHC, mini SD, micro SD,
and micro SDHC memory cards. The capacities are available up to 32 GB.
Choose that with a maximum allowable temperature of 55ºC.
(3) When the SD memory card is a mini SD, mini SDHC, micro SD, or micro SDHC
memory card, use an SD memory card converter adapter.
(4) Before writing to the SD memory card, release the write-protect switch.
(5) Before inserting or ejecting an SD memory card, make sure to power off the
system. If an SD memory card is inserted or ejected with the system powered
on, the stored data could be corrupted or the SD memory card be damaged.
*An SD memory card is live for a short duration after the system is powered off.
Before insertion or ejection wait until the LED lamps on the FTC control board
are all off.
(6) The read and write operations have been verified using the following SD mem-
ory cards, however, these operations are not always guaranteed as the specifi-
cations of these SD memory cards could change.
Manufacturer
Model
Verbatim
#44015
SanDisk
SDSDB-002G-B35
Panasonic
RP-SDP04GE1K
Arvato
2GB PS8032 TSB 24nm MLC
Arvato
2GB PS8035 TSB A19nm MLC
SanDisk
SDSDUN-008G-G46
Verbatim
#43961
Verbatim
#44018
VANTASTEK
VSDHC08
Before using a new SD memory card (including the card that comes with the
unit), always check that the SD memory card can be safely read and written to
by the FTC controller.
<How to check read and write operations>
a) Check for correct wiring of power supply to the system. For more details,
refer to section 4.5.
(Do not power on the system at this point.)
b) Insert an SD memory card.
c) Power on the system.
d) The LED4 lamp lights if the read and write operations are successfully
completed. If the LED4 lamp continues blinking or does not light, the SD
memory card cannot be read or written to by the FTC controller.
19
Meaning
Normal operation
Switch-on recommendation
Switch-off command
Switch-on command
Tested in
Mar. 2012
Oct. 2011
Oct. 2011
Jun. 2012
Jul. 2014
Oct. 2016
Oct. 2016
Oct. 2016
Sep. 2017
2. To end operation*2
● Turn OFF the indoor unit power supply.
● Turn DIP switch 4-4 and 4-5 OFF.
*2 When the indoor unit only operation is ended, ensure to check over the settings
after outdoor unit is connected.
Note:
Prolonged running of this operation may affect the life of the electric heater.
4 3 2 1
TBI.3
IN11
(7) Make sure to follow the instruction and the requirement of the SD memory
card's manufacturer.
(8) Format the SD memory card if determined unreadable in step (6). This could
make it readable.
Download an SD card formatter from the following site.
SD Association homepage: https://www.sdcard.org/home/
(9) FTC supports FAT file system but not NTFS file system.
(10) Mitsubishi Electric is not liable for any damages, in whole or in part, including
failure of writing to an SD memory card, and corruption and loss of the saved
data, or the like. Back up saved data as necessary.
(11) Do not touch any electronic parts on the FTC control board when inserting or
ejecting an SD memory card, or else the control board could fail.
Logos
Capacities
2 GB to 32 GB *2
SD speed classes
All
• The SD Logo is a trademark of SD-3C, LLC.
The mini SD logo is a trademark of SD-3C, LLC.
The micro SD logo is a trademark of SD-3C, LLC.
*2 A 2 GB SD memory card stores up to 30 days of operation logs.
IN12