N e a r F i e l d P r o b e s
H Z 5 3 0
Handbuch / Manual / Manual
Deutsch / English / Español
Tabla de contenido
loading

Resumen de contenidos para Hameg Instruments HZ530

  • Página 1 N e a r F i e l d P r o b e s H Z 5 3 0 Handbuch / Manual / Manual Deutsch / English / Español...
  • Página 2 Änderungen vorbehalten / Subject to change without notice...
  • Página 3: Tabla De Contenido

    Inhaltsverzeichnis HZ530-Sondensatz für EMV-Diagnose ........6 Technische Daten ..............7 Allgemeines ................8 Wichtige Hinweise ..............9 Betriebsbedingungen ............10 Gewährleistung ..............10 Grundlagen der Messtechnik mit Nahfeldmesssonden ..11 Die H-Feld-Sonde ..............11 Die Hochimpedanzsonde ............11 Der E-Feld-Monopol .............. 10 Inbetriebnahme ..............
  • Página 4 Messgeräten nicht zu einer Zerstörung oder Außerbetriebsetzung des Messgerätes. Geringfügige Abweichungen des Messwertes über die vorgegebenen Spezifikatio- nen hinaus können durch die äußeren Umstände in Einzelfällen jedoch auftreten Dezember 1995 HAMEG Instruments GmbH Änderungen vorbehalten / Subject to change without notice...
  • Página 5 Industriestraße 6 Nom et adresse du fabricant D - 63533 Mainhausen Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt The HAMEG Instruments GmbH herewith declares conformity of the product HAMEG Instruments GmbH déclare la conformite du produit Bezeichnung / Product name / Designation:...
  • Página 6: Hz530-Sondensatz Für Emv-Diagnose

    HZ530-Sondensatz für EMV-Diagnose Typischer Frequenzverlauf Hochimpedanz Sonde Typischer Frequenzverlauf E-Feld-Sonde Typischer Frequenzverlauf H-Feld-Sonde Änderungen vorbehalten / Subject to change without notice...
  • Página 7: Technische Daten

    Technische Daten Frequenzbereich: 100 kHz – ≥ 1000 MHz (untere Grenzfreq. abhängig von Sondentyp) 50 Ω Ausgangsimpedanz: Anschluss: BNC-Buchse ca. 2pF (Hochimpedanzsonde) Eingangskapazität: Max. Eingangspegel: +10dBm (zerstörungsfrei) 1dB-Kompressionspunkt: -2dBm (frequenzabhängig) Max. DC-Eingangsspg.: 20V Versorgungsspannung: 6V DC Versorgungsspanung durch Spektrum Analysator oder 4 x 1.5 V Mignon Zelle Stromaufnahme: ca.
  • Página 8: Allgemeines

    Prüfum gebung. Mittels eines Akkusatzes hat jede Sonde eine Betriebsdauer von ca. 20 - 30 Stunden. Der HZ530-Sondensatz besteht aus drei aktiven Breitbandsonden für die EMV-Diagnose bei der Entwicklung elektronischer Baugruppen und Geräte auf Laborebene. Er enthält eine aktive Magnetfeldson- de (H-Feld-Sonde), einen aktiven E-Feld-Monopol und eine aktive Hochimpedanzsonde.
  • Página 9: Wichtige Hinweise

    Wichtige Hinweise Allgemeines Sofort nach dem Auspacken sollten die Sonden auf mechanische Beschädigungen und lose Teile im Innern überprüft werden. Falls ein Transportschaden vorliegt, ist sofort der Lieferant zu informieren. Die Sonden dürfen dann nicht in Betrieb gesetzt werden. Symbole Bedienungsanleitung beachten Hochspannung Erde...
  • Página 10: Betriebsbedingungen

    Betriebsbedingungen Der zulässige Umgebungstemperaturbereich während des Betriebs reicht von +10°C... +40°C. Während der Lagerung oder des Trans- ports darf die Temperatur zwischen -40°C und +70°C betragen. Hat sich während des Transports oder der Lagerung Kondenswasser gebildet, müssen die Sonden ca. 2 Stunden akklimatisiert werden, bevor sie in Betrieb genommen werden.
  • Página 11: Grundlagen Der Messtechnik Mit Nahfeldmesssonden

    Grundlagen der Messtechnik mit Nahfeldmesssonden Die H-Feld-Sonde Die H-Feld-Sonde gibt einen der magnetischen Wechsel-Feldstärke proportionalen Pegel an das angeschlossene Messsystem ab. Mit ihr können Störquellen in elektronischen Baugruppen relativ eng lokalisiert werden. Dies hat seine Ursache darin, dass moderne elektronische Baugruppen als Störer meist niederohmig wirken (relativ kleine Spannungs änderungen bei entsprechend großen Stromänderungen).
  • Página 12: Der E-Feld-Monopol

    Ferner können Abnahmeprüfungen so gut vorbereitet werden, dass man im allgemeinen vor Überraschungen sicher ist. Inbetriebnahme Vor Beginn der ersten Messung mit den Sonden HZ530 sind die Hochimpedanzsonde und die E-Feld-Sonde mit den notwendigen Antennen zu versehen. Diese befinden sich in Form von ca. 0.8mm starken, geraden Drähten in einem kleinen Plastikbeutel im Trans-...
  • Página 13 Die Öffnung zur Aufnahme der Antenne befindet sich jeweils im verjüngten vorderen Teil der Sonde. Die kurze Tastspitze ist für die Hochimpedanzsonde vorgesehen. Die längere Antenne wird für die E-Feld-Sonde verwendet. Je nach vorgesehenem Frequenzbereich kommt die kürzere (ca. 6.5cm) oder längere (9.5cm) Antenne zum Einsatz.
  • Página 14: Sicherheitshinweis

    im Allgemeinen für Messungen im Abstand von 1m bis 1.5m vom zu untersuchenden Objekt eingesetzt. Die dabei ermittelten Störfrequenzen lassen sich mit der H-Feld-Sonde im Nahbereich der Störquelle lokalisieren. Die Hochimpedanzsonde ermöglicht anschließend die exakte Eingrenzung der Störquelle und die gezielte Beurteilung der getroffenen Maßnahmen.
  • Página 15: Applikationen Für Die Nahfeldsonden Hz 530

    Applikationen für die Nahfeldsonden HZ 530 Praxisorientierte Auswahl von Signalleitungsfiltern Die durch die ständig steigende Arbeitsgeschwindigkeit moderner Digitallogik über proportional wachsenden EMV-Probleme werden seit dem 01.01.1996 allen Anbietern elektrischer und elektronischer Produkte drastisch vor Augen geführt. Die neue Gesetzgebung verschärft zwar nicht die Störstrahlungsproblematik, macht aber die Auseinandersetzung mit diesen Gegebenheiten zur Pflicht für jeden Entwickler.
  • Página 16 ist 150 pF. Wenn nun ein Signal dieses Prozessors mit nur einem CMOS-Gatter, also ca. 12,5 pF, belastet wird, heißt dies, dass die Flanke etwa zwölfmal schneller wird. Es muss ein Wert von unter 200 ps erwartet werden. Rechnet man dies in die entsprechende Bandbreite des Spektrums um, so erhält man 1,6 GHz.
  • Página 17 würde das Messergebnis stark verfälscht. Deshalb benötigt man für die Messung in Digitalschaltungen eine Hochimpedanz-Sonde, die das Messobjekt nicht nennenswert belastet und das Signal breitbandig auf 50 Ω umsetzt. Im Prinzip könnte man auf den Gedanken kommen, Signallei- tungsfilter nach Katalog auszusuchen. Namhafte Hersteller bieten zu ihren Filtern die entsprechenden Messergebnisse in Zeit- und Frequenzbereich in ihren Katalogen an.
  • Página 18 sollen, wird die Eingrenzung solcher Spektren unerlässlich, will man nicht erhebliche Abschirmmaßnahmen treffen. Eine erste Maßnahme in dieser Richtung, die häufig empfohlen wird, ist das Einfügen eines Widerstandes zwischen Gatterausgang und Leitung. Die Leitung ist bei dieser Messung durch einen ein- zelnen Gattereingang abgeschlossen, um realistische Verhältnisse zu haben.
  • Página 19 Bild 3 zeigt die Resultate für eine Bestückung mit 47 Ω und 100pF. Auch hier erfolgt die Belastung des Aufbaus, wie bisher, mit der Leiterbahn und dem einzelnen Gattereingang. Im Zeitbereich ist im Vergleich zu Bild 2 kaum eine Veränderung erkennbar. Der Frequenz- bereich zeigt aber besonders im mittleren und oberen Abschnitt eine deutliche Verbesserung.
  • Página 20 eine entsprechende Anpassung der Bestückung des R-C-R-Gliedes den günstigsten Kompromiss zwischen Eingrenzung des Spektrums und der logischen Funktionalität aufsuchen. Dies ist ein besonders schönes Beispiel für die Wirksamkeit des hier vorgeschlagenen messtechnischen Verfahrens. Im Handel sind verschiedene komplette Signalleitungsfilter im An- gebot.
  • Página 21 Darstellung im Oszilloskop und die oftmals zu geringe Geschwindigkeit desselben stehen dem Erreichen der theoretischen optimalen Lösung entgegen. Für die in dieser Applikation dargestellten Messergebnisse der Freqenzspektren diente die Hochimpedanz-Sonde aus dem Nahfeld-Sondensatz HZ530 als Aufnehmer. Änderungen vorbehalten / Reservado el derecho de modificación...
  • Página 22: Messung Der Schirmdämpfung Von Abschirmgehäusen

    Aufnahme eines Breitbandspektrums von 0 bis 1000MHz in seinem Labor. Bild1 zeigt eine solche Aufnahme, die mittels aktiven E-Sonde aus dem HZ530 Sondensatz aufgenommen wurde. Im Bereich bis 50MHz zeigt sie relativ sehr hohe Pegel die von Rundfunksendern aus dem Mittel- und Kurzwellenbereich stammen.
  • Página 23 SPAN: 1000MHz CF:500MHz Hintergrund- Spektrum Bild 8 RESBW: 10kHz VIDBW: 10kHz Die Aufnahme des Hintergrundspektrums dient allerdings nicht nur der Prüfung der Sondenempfindlichkeit. Sie soll im Falle, dass man die folgenden Messungen nicht in der Schirmkabine ausführen kann als Referenz dienen, um die wichtigsten Spektrallinien erkennen zu können die nicht aus der zu untersuchenden Elektronik stammen.
  • Página 24 SPAN: 1000MHz CF:500MHz Störer mit Abschirmung Bild 10 RESBW: 10kHz VIDBW: 10kHz Bild 10 zeigt das Resultat. Man sieht, dass die Abstrahlung im gesamten Frequenzbereich geringer geworden ist. Aus den Pe- geldifferenzen aus Bild 2 und Bild 3 kann die Schirmdämpfung für verschiedene Frequenzen ermittelt werden.
  • Página 25: Commonly Asked Questions About Pre-Compliance Emissions Testing

    Table of contents Near Field Sniffer Probes HZ 530 ..........26 Specifications ................26 General Information ............... 27 Important Hints ................28 Safety .................... 28 Operating Conditions ..............29 Warranty ..................29 Introduction ................... 30 Operation of the Probes ..............31 Battery Operation ................
  • Página 26: Near Field Sniffer Probes Hz 530

    Near Field Sniffer Probes HZ 530 Specifications Frequency range: 0.1MHz to ≥1000MHz (lower frequency limit depends on probe type) Output impedance: 50Ω Output connector: BNC-jack Input capacitance: 2pF (high imped. probe) Max. Input Level: +10dBm (without destruction) 1dB-compression point: -2dBm (depends on frequency range) DC-input voltage: 20V max.
  • Página 27: General Information

    General Information The HZ530 is the ideal toolkit for the investigation of RF electroma- gnetic fields. It is indispensable for EMI pre-compliance testing during product development, prior to third party testing. The set includes 3 hand-held probes with a built-in pre-amplifier covering the frequency range from 100 kHz to over 1000 MHz.
  • Página 28: Important Hints

    Important Hints Users are advised to read through these instructions so that all func- tions are understood. Immediately after unpacking, the instrument should be checked for mechanical damage and loose parts in the interior. If there is transport damage, the supplier must be informed immediately.
  • Página 29: Operating Conditions

    Specifications: Values without tolerances are typical for an average instrument. Warranty HAMEG instruments are subjected to a rigorous quality control. Prior to shipment each instrument will be burnt in for 10 hours. Intermit- tent operation will produce nearly all early failures. After burn in, a final functional and quality test is performed to check all operating modes and fulfilment of specifications.
  • Página 30: Introduction

    “Pre-Compliance” phase in product development first be conducted. This phase would use a spectrum analyzer such as the HM5010 in conjunction with HZ530 close field sniffer probes, to inspect for emission and leakage; isolate the source, design and correct the problem and then retest.
  • Página 31: Operation Of The Probes

    Operation of the Probes Before performing measurements with two of the HZ530 probes, the High Impedance (Hi-Z) Probe and the E-Field Probe they must be configured for testing. The 0.8 mm diameter wires which are used as antennas are located in the plastic bag that is in the case for the probes.
  • Página 32: Use Of Different Probe Types

    used, the insertion loss of this cable must be added to the output values at the higher frequencies. For the normal measurements, the probes are connected to a spectrum analyzer. These instruments generally have an input Ω impedance of 50 .
  • Página 33: Accuracy Notice

    whenever possible, be made by use of the supplied 1.5 m supply cable connected to the spectrum analyzer. If this is not possible, rechargeable batteries should be used. If non-rechargeable batteries are used, they should be disposed of properly. Accuracy Notice The probes may not be used to perform accurate quantitative measurements.
  • Página 34: The High-Impedance Probe

    development components which are not suitable for EMC purposes. The effectiveness of countermeasures can be judged easily. One can investigate shields for “leaking” areas and cables or wires for conducted interference. The High-Impedance Probe The high-impedance probe (Hi-Z) permits the determination of the radio frequency interference (RFI) on individual contacts or printed circuit traces.
  • Página 35: Hz530 Near-Field Probe Applications Practical Selection Of Signal-Line Filters

    HZ530 Near-Field Probe Applications Practical Selection of Signal-Line Filters The steadily increasing operating speed of modern digital logic causes significantly greater concerns with EMC problems. This has become more noticed by all manufacturers of electrical and electronic devices since 1 January l996, the effective compliance date for the European Union EMC Directive.
  • Página 36 50 Ω system over a wide frequency range. The following measurement results were measured with the High Impedance Probe HZ530 connected to a Spectrum Analyzer and with a digital scope. In principle, it is easy to assume that it is possible to select signal-...
  • Página 37 line filters from catalog values. Well-known manufacturers offer filters with measurement data in the time- and frequency- domain. Unfortunately, the filter data is performed with an entirely resistive load and therefore the data looks very good. However, in practice an entirely resistive circuit seldom exists. Therefore, the filters must be evaluated when installed in a practical circuit.
  • Página 38 Figure 2 shows the results when a 47 Ω resistor is used. In the time domain a significant improvement occurs. The overshoot is reduced and the risetimes are somewhat slower. The linear dyna- mic range of an oscilloscope can not demonstrate adequately the EMC characteristics of the signal.
  • Página 39 suppression measure is not noticeable. The next step is to insert a 47 Ω, 100 pF, 47 Ω T-filter. Figure 4 shows that the change is quite noticeable when compared to Figure 3. The frequency range is now practically reduced to 200 MHz.
  • Página 40 R combination in surface mount technology (SMT). Some offered three-pole capacitors are poor high frequency filters. Another example is a wideband choke used as a signal line filter. Figure 6 shows the results. The frequency spectrum is poorly suppressed, but the risetimes are significantly slowed down. It should be noticed here that a time domain analysis only will lead to poor EMC performance and the wrong conclusions.
  • Página 41: Measurement Of The Shielding Attenuation Of Shielded Housings With The E-Field Probe

    0 to 1,000MHz. Figure 8 shows the result of such a measurement which was made with the active E-field probe from the HZ530 probe kit connected to a spectrum analyzer. From 0 to 50MHz, Figure 8 shows relative high levels which originate from transmitters in the broadcast band and shortwave region.
  • Página 42 lines which are significantly above the noise level. Of course, the spectrum display will be different at each location depending on the relative distance of transmitters. Even in rural areas cellular telephone lines must show the absence of which would show that the probe has insufficient sensitivity at the higher frequencies.
  • Página 43 until the maximum RFI is observed. The direction may be different than in the non-shielded equipment. EUT RFI Characteristics with the Additional Shielding Figure 10 Figure 10 shows the data with the additional shield. By comparing Figure 10 with Figure 9, it is observed that the entire spectrum is lower.
  • Página 44: Commonly Asked Questions About Pre-Compliance Emissions Testing

    EMC test equipment and then establish how they differ. HAMEG Instruments has considerable experience with both types of equipment. We use high-cost equipment for compliance testing and also specify and design low-cost pre-compliance equipment.
  • Página 45 costly to implement. Pre-compliance instruments provide valuable measurements and possess some of the features of compliance equipment. Generally, though, precompliance instruments do not need to conform fully to CISPR 16 and therefore can cost less. Compliance equipment is your first choice if money is no object. In reality, often you cannot justify the cost of such equipment and need a more economical approach.
  • Página 46 If you are going down to detect the source of the radiation (e.g. a transistor, IC, or any other component) on the contact-level, the high-impedance probe of the HZ530 probe set is indispensable for measurements due to its ultra-low input capacitance of 2pF only.
  • Página 47 You can overcome this limitation by using a 3-meter test distance, or by use of a pre-selector or preamplifier (which is built-in for example in the E-Field probe of the HZ530) with the spectrum analyzer. Each of these methods effectively increases the limit or reduces the noise floor of the measurement.
  • Página 48 E-Field probe is used, which is used as broad bandwidth measurement antenna to help answer the above questions. Does the E-Field-Monopole of the HZ530 have sufficient sensitivity for pre-compliance testing? First, before the E-field probe is used, determination must be made if the probe has sufficient sensitivity and bandwidth.
  • Página 49 Índice Conjunto de sondas HZ530 para la diagnosis de EMC ... 50 Datos técnicos ..............50 Generalidades ..............51 Información general ............52 Símbolos ................. 52 Seguridad ................ 52 Condiciones de funcionamiento ........53 Garantía ................53 Principios básicos de la técnica de medida con sondas de campo cercano ........
  • Página 50: Conjunto De Sondas Hz530 Para La Diagnosis De Emc

    Conjunto de sondas HZ530 para la diagnosis de EMC Datos técnicos Margen de frecuencias: 100kHz - ≥1000MHz (frecuencia límite inferior dependiente del tipo de sonda) Impedancia de salida: 50Ω Conexión: Borne BNC Capacidad de entrada: aprox 2pF (sonda de alta impedancia) Nivel de entrada máx.: +10dBm (no deteriorable)
  • Página 51: Generalidades

    (aprox. 30 dB) hacen innecesario la utilización adicional de aparatos externos, hecho que facilita el manejo considerablemente. El conjunto de sondas HZ530 se compone de tres sondas activas de banda ancha para la diagnosis de EMC durante el diseño de gru- pos electrónicos y aparatos.
  • Página 52: Información General

    Información general Después de desembalar las sondas, compruebe primero que estas no tengan daños externos ni piezas sueltas en su interior. Si muestran daños de transporte, hay que avisar inmediatamente al suministrador o transportista. En tal caso no ponga las sondas en funcionamiento Símbolos Atender las instrucciones de manejo...
  • Página 53: Condiciones De Funcionamiento

    Condiciones de funcionamiento El margen de temperatura ambiental admisible durante el funcionami- ento va desde +10°C hasta +40°C. La temperatura permitida durante el almacenaje y el transporte es de 40°C hasta +70°C. Si durante el almacenaje se ha producido condensación, habrá que climatizar las sondas durante 2 horas antes de ponerlas en marcha.
  • Página 54: Principios Básicos De La Técnica De Medida Con Sondas De Campo Cercano

    Principios básicos de la técnica de medida con sondas de campo cercano Sonda de campo H La sonda de campo H suministra al analizador de espectros un nivel proporcional a la intensidad del campo alterno. Esto permite localizar en un margen relativamente estrecho ruidos de grupos electrónicos. El origen está, en que los grupos electrónicos de moderna gener- ación generan ruidos de baja impedancia (variaciones de tensión relativamente pequeñas con variaciones de intensidad relativamente...
  • Página 55: Sonda Monopolo De Campo E

    conexiones de IC como fuentes de ruido. Dentro de la circuitería se pueden localizar las zonas problemáticas. Mediante esta sonda se puede hacer accesible cualquier punto del circuito al analizador de espectros. Sonda monopolo de campo E El monopolo de campo E tiene la mayor sensibilidad de las tres sondas.
  • Página 56: Puesta En Funcionamiento

    Puesta en funcionamiento Antes de comenzar la medición con las sondas HZ530 se les deben acoplar a la sonda de alta impedancia y a la sonda de campo E las antenas correspondientes. Estas se suministran en una bolsita de plástico que contiene la maleta de transporte y tienen el aspecto de unas varillas de 0,8mm de espesor.
  • Página 57: Indicación De Seguridad

    Las sondas están previstas para diferentes aplicaciones, según sus características eléctricas. La sonda de campo E se utiliza normalmente para distancias de 1 a 1,5 m del objeto a analizar. Las frecuencias perturbadoras se pueden captar con la sonda de campo H en las inmediaciones de la fuente de emisión.
  • Página 58: Aplicaciones Para Las Sondas De Campo Cercano Hz530

    Aplicaciones para las sondas de campo cercano HZ530 Elección práctica de filtros de conductos de señal Los problemas en EMC que se ocasionan a través de la velocidad de trabajo creciente de la lógica digital moderna, se constatan drásticamente a los producentes de productos eléctricos y elec- trónicos desde el 01.01.1996.
  • Página 59 Bajo aspectos EMC esto es realmente dañino. La velocidad real de flanco pero, en los circuitos con CMOS, no es medible en la mayoría de laboratorios digitales técnicos. Para esto se precisan osciloscopios que puedan presentar señales de 100ps y estos sólo se obtienen en base a un gran desembolso monetario.
  • Página 60 Anritsu 2601A, así como de un osciloscopio Hewlett-Packard 54502A con sonda HP10430A. Como receptor se utilizó la sonda de alta impedancia del conjunto HZ530. En principio se podría tener la idea, de seleccionar los filtros en conductos de señal, por catálogo. Hay fabricantes importantes que ofrecen sus filtros en catálogos con las características técnicas...
  • Página 61 cubre toda la gama desde 1000MHz. Realmente lo sobrepasa, pero los espectros de las imágenes presentes van con escalas hasta los 1000MHz, para permitir una mejor comparación. En el margen del tiempo se observan variaciones importantes de sobreoscilaciones así como flancos empinados. Esta señal se puede determinar como muy mala respecto a su EMC.
  • Página 62 la elección del valor de la resistencia se puede modificar en algo el resultado actual, pero la variación no será espectacular. Otra mejora se conseguirá combinando la resistencia mediante un condensador a un conjunto RC. Figura 3 La figura 3 muestra los resultados de una composición con 47 Ω y 100pF.
  • Página 63 en este momento , si la funcionalidad lógica del circuito digital ha sufrido algún perjuicio. Pero en así un caso se puede buscar un compromiso adaptando el componente R-C-R entre la limitación del espectro y la funcionalidad lógica. Este es un buen ejemplo para la eficacia del procedimiento de medición descrito.
  • Página 64: Medición De La Atenuación De Aislamiento De Blindajes Mediante La Sonda De Campo E

    En la figura 6 se puede observar el resultado: aquí también apa- rece una delimitación insuficiente a pesar de la ralentización del flanco. Obsérvese: sería erróneo analizar únicamente el tiempo y sería una medida cara que carga la función digital con resultados decepcionantes en lo que se refiere a EMC.
  • Página 65 0 hasta 1000MHz en su laboratorio. La figura 1 presenta así una imagen, obtenida mediante la sonda activa E del conjunto de sondas HZ530. En el margen hasta 50MHz se visualizan niveles altos de señal, procedentes de las emisoras de radio de onda media y corta.
  • Página 66 que no se puedan realizar las mediciones en una cabina blindada, como referencia, para reconocer las líneas espectrales más impor- tantes que no provienen del producto electrónico elaborado. Ruidos sin blindaje Figura 9 Para realizar la medición se posiciona el objeto a medir a una di- stancia de 0,5m de la sonda sin blindaje.
  • Página 67 en la realidad. Las mediciones se obtuvieron con un contador de frecuencias de bajo coste. Hay cantidad de aparatos, cuyas cajas metálicas no proporcionan valores mejores. Es por esto realmente aconsejable medir antes de desembolsar demasiado dinero por chapa con un factor de aislamiento insuficiente. Änderungen vorbehalten / Reservado el derecho de modificación...
  • Página 68 . h a m e g . c o m Subject to change without notice HAMEG Instruments GmbH Subject to change without notice HAMEG Instruments GmbH 40-0530-0000 / 07112013 Industriestraße 6 43-2030-2010 (10) 21092011 Industriestraße 6 © HAMEG Instruments GmbH © HAMEG Instruments GmbH D-63533 Mainhausen D-63533 Mainhausen A Rohde & Schwarz Company Tel +49 (0) 61 82 800-0 A Rohde & Schwarz Company Tel +49 (0) 61 82 800-0 DQS-Certification: DIN EN ISO 9001:2000...