F. Through The Wall
Horizontal termination cap must be a minimum of 6
inches. (152mm) from the wall. Approved for mobile home
installations. Must use 3 or 4 inch (76-102mm) "L" or "PL"
listed pellet venting or Listed double wall pipe and an
authorized Outside Air Kit in mobile homes.
NOTICE: Please note that while the minimum clearance
for the termination cap is 6 inches (152mm)
there is the possibly of soot build-up around
the termination area. If this occurs we suggest
to move the termination further away from the
house to prevent it. The suggested minimum
is 12 inches.
Straight Out
45 Degrees
(254mm)
Minimum
6 in.
(152mm)
Minimum
From Glass
Illustration shows venting going in both directions.
Choose which one is best for your installation.
Wall
Thimble
6 in (152mm)
Minimum
3 in.
(76mm)
Minimum
7077-801D • September 17, 2019
NOTE: In Canada, where passage through a wall or
partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365
CAUTION
DO NOT DOWNWARD VENT.
The following will occur:
•
The appliance will not vent properly
•
Smoke spillage in the house
•
Excessive sooting
10 in.
Horizontal
Wall
Termination
Thimble
Cap
6 in.
(152mm)
Minimum
Non-combustible Hearth Pad
6 in (152mm) Minimum
3 in. (76mm)
Minimum
31