MULTIPROCESS WIRE FEEDER WELDER
INSTALLATION
TECHNICAL SPECIFICATIONS -
INPUT VOLTAGE AND CURRENT
Duty Cycle
Input Voltage
(Output)
60% FOR MIG
120
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input Amperes
Voltage/Phase/
Frequency
Effective
120/1/60
PHYSICAL DIMENSIONS
Height
Width
13.6"
8.9"
(345MM)
(224MM)
WELDING PROCESSES
Electrode Diameter
Process
Range
.025-.035"
MIG
( 0.6-0.9MM)
.030-.035"
FCAW
(0.8-0.9MM)
.040, 1/16, 3/32"
TIG
(1.0, 1.6MM, 2.4MM)
UP TO 3/32"
STICK
(2.4MM)
*Max wire feed speed achieved with a spool gun
TEMPERATURE RANGES
Operating
-4°F TO 104°F (-20°C TO 40°C)
Temperature
Storage
-40°F TO 185°F (-40°C TO 85°C)
Temperature
Thermal tests have been performed at ambient temperature. The duty
cycle (duty factor) at 40°C has been determined by simulation.
SELECT SUITABLE LOCATION
Place the machine on a secure, level surface or recommended
undercarriage. The machine may topple over if this procedure is
not followed. To minimize over heating, locate the welder in a dry
location where there is free circulation of clean air. Do not place
on combustible surfaces.
Input Amperes
Idle Amps
Max
20
.7
Fuse (Super Lag) or
Breaker Size
15
20
Depth
Weight
18.1"
34.5 LBS.
(460MM)
(15.6 KG)
Output Range
Wire Feed
(Amperes)
Speed Range
20-140
40-500* IPM
20-140
40-400 IPM
10-120
NA
25-90
NA
WELDING PROCESSES
Process
Duty Cycle
MIG & FCAW
60%
TIG
60%
STICK
60%
The machine is capable of higher duty cycles at lower output
currents or higher amperages at lower duty cycles. An overview
of the machine's input and output capabilities are available on the
rating plate located on the back of the machine.
REGULATORY REQUIREMENTS
Market
Conformity Mark
USA AND CANADA
LOCATION AND MOUNTING
The welding machine will operate in harsh environments. Even so,
it is important that preventative measures are followed in order to
assure long life, reliability, and safe operation.
• The welding machine must be located in an area with
circulation of clean air such that air moves in the back of the
machine and out the front louvers.
• Dirt and dust that can be drawn into the welding machine
should be kept to a minimum. Failure to observe these
precautions can result in excessive operating temperatures,
nuisance thermal trips and potential failures.
ENVIRONMENTAL RATING
The welding power source carries an IP21S rating. It may be used
in normal industrial and commercial environments. Avoid using in
areas where water / rain is present.
Read and follow the 'Electric Shock Warnings' in the safety section
if welding must be performed under electrically hazardous
conditions such as welding in wet areas or water on the work
piece.
ENGINE DRIVEN GENERATOR
The machine is designed to operate on engine driven generators as
long as the auxiliary can supply adequate voltage, frequency and
power as indicated in the "Technical Specification" Installation
Section of this manual. The auxiliary supply of the generator must
also meet the following conditions:
Frequency: 60 Hz
RMS voltage of the AC waveform: 90-140 V; Out of this range will
trigger undervoltage and overvoltage protections.
Generator Minimum 3 kW
It is important to check these conditions because many engine driven
generators produce high voltage spikes. Operation of this machine
with engine driven generators not conforming to these conditions is
not recommend and may damage the machine and is also NOT
covered by warranty.
A-1
INSTALLATION
Amperage
Voltage
95 AMPS
18.75 VOLTS
115 AMPS
14.6 VOLTS
80 AMPS
23.2 VOLTS
Standard
IEC 60974-1
CSA
C
US
IEC 60974-5