Genius JA383 Instrucciones Para El Uso página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Connection of two pairs of closing photocells and two
edge safety devices
1
2
3
RX CL1
1
2
3
4
-
+
5
TX CL2
1
2
Fig. 11
Connection of a pair of closing photocells, a pair of opening
photocells and a pair of opening/closing photocells
1
2
3
4
RX CL
1
2
3
4
-
+
5
1
2
TX OP/CL
RX OP
1
2
3
4
-
+
5
-
-
4
5
6
7
8
9 10 11 12
TX CL1
-
1
+
2
RX CL2
1
2
3
4
5
-
-
5
6
7
8
9 10 11 12
TX CL
1
-
+
2
1
2
3
4
5
RX OP/CL
TX OP
1
-
+
2
Fig. 12
Connection of a pair of closing photocells and a pair of
opening/closing photocells
1
2
3
RX CL
1
2
3
4
-
+
5
1
2
TX OP/CL
Connection of two N.O. contacts in parallel
(e.g. Open A, Open B)
4.2. J7 Terminal board - Power supply (fig. 2)
POWER SUPPLY (terminals PE-N-L):
PE: Earth connection
N : 115 V~ power supply ( Neutral )
L : 115 V~ power supply ( Line )
NB.: For correct operation, the board must be connected to the
earth conductor in the system. Install an adequate differential
thermal breaker upstream of the system.
4.3. J6 Terminal board - Motors and flashing lamp (fig. 2)
MOTOR - (terminals 13-14-15): Motor connection.
In gearmotors with a built-in control unit, this connection is pre-
wired standard. For leaf opening direction, see basic
programming in Chpt 5.1.
LAMP - (terminals 16 -17): Flashing lamp output ( 115 V ~)
4.4. J1 Terminal board - Accessories (fig. 2)
OPEN A - "Total Opening" command (terminal 1): any pulse
generator (push-button, detector, etc.) which, by closing
a contact, commands total opening and/or closing of the
gate leaf.
To install several total opening pulse generators, connect
the N.O. contacts in parallel
OPEN B - "Partial opening " or "Closing" command (terminal
2): any pulse generator (push-button, detector, etc.)
which, by closing a contact, commands partial opening
and/or closing of the gate leaf. In the B and C logics, it
always commands gate closure.
To install several partial opening pulse generators, connect
the N.O. contacts in parallel (see fig. 14).
11
ENGLISH
-
-
4
5
6
7
8
9 10 11 12
TX CL
-
1
+
2
1
2
3
4
5
RX OP/CL
(see fig. 14).
Fig. 13
Fig. 14
Tabla de contenido
loading

Tabla de contenido