Hydraulic power pack with load sensing variable displacement pump and constant displacement pump
Hydraulic safety
•
Depressurize the system!
–
Switch off the compressed air supply before working on the circuit.
–
Check the system using pressure gauges to make sure that the entire circuit is fully depressurized.
–
Please note that energy may be stored in reservoirs.
Further information on this issue is available in the data sheets and operating
instructions included with the components.
•
Limit system pressure to 6 MPa or 6.5 MPa (60/65 bar).
•
Risk of injury due to oil temperatures greater than 50° C!
Hydraulic oil with a temperature greater than 50° C may result in burns or scalding.
•
Risk of injury when switching on the hydraulic power pack!
Cylinders may advance and retract automatically.
•
Connecting the hoses
–
Never connect or disconnect the hoses when the hydraulic power pack is running,
or while under pressure!
Couplings must be connected when unpressurized.
–
Place the coupling socket vertically onto the coupling nipple.
The coupling socket and the coupling nipple must not be fitted askew.
–
After each disconnection, make sure that the couplings have closed themselves!
•
Before commissioning, make sure that all tank lines have been connected and that all couplings have
been fitted securely.