RUN SELF-LEARNiNG ANd ANTi-CRUSHiNG dEViCE SETTiNG
When operator assembly and wiring is completed, parameters and logic are programmed, self learning allows the operator
to learn the stroke and self adjusts amperometric sensor thresholds.
First of all place the opening and closing mechanical stops:
- manually release the door and completely close it. Place the closing mechanical stop in the closed position on the
driving carrier and fix it.
- completely open the door. Place the opening mechanical stop in the open position on the driving carrier and fix it.
For further information, please refer to the operator (JM4) manual.
Now the opening and closing positions can be memorized:
Enter menu Auto and press the button < PGM > , PUSH will be displayed.
Press again the button < PGM >: self-learning is beginning: PRG will be displayed, and the control panel completes at
least two opening/closing cycles.
When the procedure is completed OK will be displayed.
This procedure can be followed from any position of the gate/door leaf and can be stopped at any moment by pressing
keys <+> and <-> at the same time, or through the activation of STOP/PHOTO/PP/CLOSE inputs.
At the end of the self-setting, the PMO and PMC parameters, if previously modified, are shown as default values. If the
procedure is not successful, the wording ERR appears. Check that no obstacles or frictions are present.
IMPORTANT: The torque value also includes changes in the resistance of the door during movement. The entire stroke
is divided in 64 opening points and 64 closing points where the optimal operating torque is read and memorised by the
control unit.
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and
setting the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the
software release.
USE oF PRoGRAmmiNG KEYS
Press <PG> key to gain access to the Main Menu (PAR>>LOG>>RADIO>>...). These keys can be selected by pressing +
and – keys.
Select the Main menu with <PG> key to enter the desired Function Menu .
• If <+> is pressed, the Function Menu can be scrolled from top to bottom.
• If <-> is pressed, the Function Menu can be scrolled from bottom to top.
• If <PG> key is pressed, presetting to be modified can be entered.
• The preset values can be modified by using <+> and <-> keys.
• The value is programmed if <PG> key is pressed again. The word "PRG" appears on the display.
NOTES:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without mak-
ing any changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
Pressing <-> with the display turned off means an impulse of P.P.
In the charts following the single available functions are described in the plant.
mENU
Automatic closure time. It is enabled only with "TCA"=ON logic.
TCA
At the end of the preset time, the control unit controls a closure operation.
Braking during closure is adjusted.
The value is expressed in percentage on the aggregate value of the stroke.
tsm
In the opening phase, braking is automatically preset by the control unit
and no adjustment is required.
FSTS
The opening and closing speed is adjusted.
sldS
Speed during braking is adjusted.
14

PRoGRAmmiNG

PARAmETERS, LoGiC ANd SPECiAL FUNCTioNS
PARAmETERS (PAR)
FUNCTioN
mEmo
miN-mAX-(default)
1-240-(40s)
1-99-(20%)
1-99-(99)
1-99-(20)