TECHNiCAL DATA
Mains power supply
Output, Motor
Motor maximum power
Output, power supply of accessories
Protection level
Operating temperature
Radio receiver
No. of codes storable in memory
Terminals
Function
L-N-GND
Power supply
4-5
Flashing light
6-7-8
Motor 2
9-10-11
Motor 1
12-13
ELS/SRL
14-15
24 VAC
16-17
SCA
18-19
2CH/TX.
20-21
Antenna
22
PED
23
Step-by-Step
24
STOP
25
PHOT
26
COM
F1: F6.3A (230VAC) / F10A (115VAC) – Motor protection
F2: T100mA (230Vac) - T200mA (115Vac) – Protection for primary transformer
1) Cut-off power supply.
2) Manually release the wings, move them to approx. half-stroke and lock them again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button ->.
5) The wings should start an OPENING movement.
If this is not the case, invert the movement wires of the motor (9<>11 for motor M1, and 6<>8 for motor M2).
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the
desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
12
230 VAC 50/60 Hz (115VAC 50/60 Hz for HEADY 115)
1/2 motor 230VAC (115V for HEADY 115)
500W + 500W
24VDC 500mA max.
IP54
-20°C / +70
C
°
433,92 MHz, incorporated and configurable
64
HEADY CoNTRoL UNiT
iNPUT/oUTPUT FUNCTioNS
Input, mains power supply.
HEADY:230VAC 50/60Hz (/1-Phase/2-Neutral 3-GND)
HEADY115: HEADY:230VAC 50/60Hz (/1-Phase/2-Neutral 3-GND)
Connection of flashing light, 230VAC 40W max, or 115VAC 40W max, for HEADY 115.
Connection to motor 2: 6-move/7-Com/8-move)
Connection to motor 1: 9-move/10-Com/11-move)
Normally Open free tension contact for courtesy light or electric lock See TLS parameter
Output, power supply of accessories, 24VAC/0.5A max
N.O. free-tension contact for open gate warning light With open gate the contact is closed,
flashing light during operation and open contact with closed gate.
Output, second radio channel of the integrated receiver or photocell power supply in photo
test mode.
N.O. tension-free contact. See wire diagram, Fig 1.
Connection of extractable radio receiver card to antenna (20-signal/21-monitor).
Input, push-button for pedestrian opening (Normally Open contact) The total opening of motor
1 is carried out.
Input, Step-by-Step push-button (Normally Open contact) See P.P. Logics
Input, STOP push-button (Normally Closed contact)
Input, photocell active in the opening and/or closing phase (Normally Closed contact) See
PHCL Logics
Common, for control inputs.
FUSES
To CHECK CoNNECTioNS:
PRoGRAmmiNG
Description