Before programming the control unit, check that the motor is correctly connected:
1) Cut off power supply.
2) Manually release the gate leaf, move the same at approx. half stroke and block it again.
3) Power the system again.
4) Send a step-by-step control through a NC push-button temporarily connected to the PP input.
5) The gate leaf should open.
If not, reverse the motor connector (M+/M-) and limit switches by reversing the fasto connectors on the microswitches
and perform a new self-learning of the stroke.
6) Carry out the self-learning of the stroke and trigger thresholds, as shown hereunder in the AUTO menu.
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and
setting the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the
software release.
USE OF PROGRAMMING KEYS
Press <PG> key to gain access to the Main Menu (PAR>>LOG>>RADIO>>...). These keys can be selected by pressing +
and – keys.
Select the Main menu with <PG> key to enter the desired Function Menu .
• If <+> is pressed, the Function Menu can be scrolled from top to bottom.
• If <-> is pressed, the Function Menu can be scrolled from bottom to top.
• If <PG> key is pressed, presetting to be modified can be entered.
• The preset values can be modified by using <+> and <-> keys.
• The value is programmed if <PG> key is pressed again. The word "PRG" appears on the display.
See paragraph "Programming Example".
NOTES:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without mak-
ing any changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
Pressing <-> with the display turned off means an impulse of P.P.
In the tables hereunder the single functions available in the control unit are shown.
MENU
Automatic closure time. Active with logic "TCA"= ON only.
TCA
At the end of the preset time, the control unit sends a closure control
signal.
The stroke time of the gate leaf is adjusted during the partial opening
Tped
phase controlled by the pedestrian input.
TSM
The gate leaf stroke during the braking phase is adjusted.
The anti-crash device* (amperometric sensor) operation is adjusted in the
PMo
opening phase, at normal speed.
1: maximum sensitivity - 99:minimum sensitivity.
The anti-crash device* (amperometric sensor) operation is adjusted in the
PMC
closing phase, at normal speed.
1: maximum sensitivity - 99:minimum sensitivity.
The anti-crash device* (amperometric sensor) operation is adjusted in the
PSo
opening phase, at reduced speed.
1: maximum sensitivity - 99:minimum sensitivity.
The anti-crash device* (amperometric sensor) operation is adjusted in the
PSC
closing phase, at reduced speed.
1: maximum sensitivity - 99:minimum sensitivity.
12
TO CHECK CONNECTIONS

PROGRAMMING

PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
FUNCTION
An incorrect setting of these parameters may cause danger.
Please comply with regulations in force!
* WARNING:
MEMO
MIN-MAX-(Default)
1-240-(40s)
1-99-(50%)
20-250-(50cm)
1-99-(50%)
1-99-(50%)
1-99-(50%)
1-99-(50%)