Connection Diagrams - Axis Communications A1001 Manual De Instalación

Controlador de puerta de red
Idiomas disponibles
  • ES

Idiomas disponibles

AXIS A1001 Network Door Controller
Back tampering alarm (TB)
Front tampering alarm (TF)
Function
Back tampering alarm
Front tampering
alarm
Note
Both the front and back tampering alarms are connected by default. The casing open
trigger can be configured to perform an action if the door controller is opened or if the
door controller is removed from the wall or ceiling. For information about how to configure
alarms and events, see the User Manual.

Connection Diagrams

Connect devices according to the hardware pin chart generated through the hardware
configuration. For more information about hardware configuration and the hardware pin chart, see
Configure the hardware on page 42.
Pin
Notes
1–2
To bypass the front and back tampering alarm
simultaneously, connect jumpers between TB 1, TB 2 and
1–2
TF 1, TF 2 respectively. Bypassing the tampering alarms
means that the system will not identify any tampering
attempts.
28