Power & Relay Connector (Pwr, Relay) - Axis Communications A1001 Manual De Instalación

Controlador de puerta de red
Idiomas disponibles
  • ES

Idiomas disponibles

NO
NO TICE
NO
TICE
TICE
If the lock is non-polarized, we recommend you to add an external flyback diode.
Important
The output circuits in this section are Class 2 power limited.
Power & relay connector
6-pin terminal block with built-in relay for:
External devices
Auxiliary power (DC output)
0 V DC (-)
Connect locks and loads to the pins according to the hardware pin chart generated through the
hardware configuration.
Function
Pin
1, 4
0 V DC (-)
2–3
Relay
5
12 V DC
6
24 V DC
NO
NO TICE
NO
TICE
TICE
If the lock is non-polarized, we recommend you to add an external flyback diode.
Important
The output circuits in this section are Class 2 power limited.
Tampering Alarm Pin Header
Two 2-pin headers for bypassing:
AXIS A1001 Network Door Controller
Notes
For connecting relay devices. Use the
hardware pin chart. See Configure the
hardware on page 42.
The two relay pins are galvanically
separated from the rest of the circuitry.
For powering auxiliary equipment.
Note: This pin can only be used as
power out.
Not used
27
Specifications
0 V DC
Max current = 700 mA
Max voltage = +30 V DC
Max voltage = +12 V DC
Max load = 500 mA
EN