CHAP. 5.
MAINTENANCE, BREAKS RESEARCH AND CLEANING
MAINTENANCE MAN REQUIREMENTS
With the term "maintenance" must not be understood only the periodical check of the machine normal functioning but also
the analysis and the consequent remedy of all causes that for any matter put it out of service. It is absolutely necessary that for
the maintenance, cleaning, parts change and breaks research activities performed from the user, this work is entrusted to
skilled personnel, competence and authorized from the employer.
All operations of maintenance, cleaning and parts change, none excluded, must be definitely performed with the machine
completely stopped and insulated from the external feeding sources.
MAINTENANCE PRESCRIPTIONS, DAMAGES RESEARCH AND CLEANING
PROTECTIONS REMOVAL AND/OR PROTECTION DEVICES
For the interventions of the present charter, it isn't necessary to remove from their position both fixed shelter both
moving one.
INSULATION FROM THE EXTERNAL FEEDING SOURCES
Before to perform any operation of maintenance, cleaning and parts change, the external feeding sources must be sectioned
and insulated:
1.
Position on "zero" the protection device placed upstream of the electric equipment feeding line.
2.
Disconnect the general sectioning device and provide to protect the plug with proper systems
3.
Close the drinking water tap,
4.
Slacken and unscrew completely the drinking water flexible pipe union from the tap.
BREAKS OR DAMAGES RESEARCH AND MOVING ELEMENTS UNBLOCKING
Here follow are indicate the interventions for the breaks or damages research and moving elements unblocking which can
be performed from maintenance men.
TYPE
POTENTIAL CAUSE/S
General Black out
Net voltage
Fuses or magneto thermals intervention
lacking
place upstream of the machine feeding
line
Protection device intervention inside
the machine
Functioning
intervention
Unblock and opening of the
transparent superior cover or of the
discharge lateral door (if any)
Cause/s not identifiable
Feeding voltage lacking.
Sectioning devices on "O".
Lacked working time setting
Intervened fuses or not functioning
The machine
magneto thermals.
doesn't function:
Lacked buttons functioning.
the flat doesn't
rotate
Damaged micro switches
Slow drive belt determines also noise
or creaking emission
Worn flat surface
The potatoes peel
or the mussels
Abrasive cloth surface inside the worn
scrape don't
basin
happen in a
correct way.
Drinking water flexible pipe not
Drinking water
connected
Tap closed
absence inside the
basin during the
Water emission nozzle inside the
functioning
obstructed basin
Damage in the plant inside the machine
Excessive water
Dross separation filter obstructed
presence inside
the basin that
Drawer in steel in the body inferior
doesn't discharge
zone mal inserted
or splash in the
machine inferior
Presence of losses from the lateral
zone
discharge pipe union
MODALITY AND COMPARISONS
Contact the electric energy distributor
After having eliminated the causes that have determined the protection device
intervention, restore it. In case of problem persistency contact an electrician
technician.
Contact an electrician technician: after having eliminated the causes that have
determined the protection device intervention, restore it.
In case of fuses intervention, change them with types of the same model,
calibration and intervention curve.
Unblocking and opening the cover or the door, the machine stops immediately
for the safety micro switches functioning.
Close and block the cover and the door handles.
Contact directly the Authorized Assistance Center
Check and restore the electric energy.
Turn the sectioning devices in the position "ON "
Set the timer in the controls panel
Change the intervened fuses, check the magneto thermal switches condition.
Check the buttons efficiency and eventually contact directly the Authorized
Assistance Centre.
Contact directly the Authorized Assistance Centre
Contact directly the Authorized Assistance Centre
Contact directly the Authorized Assistance Centre for the change
Contact directly the Authorized Assistance Centre for the change
Connect the drinking water flexible pipe, screwing the piping union to the tap
male joint
Rotate the superior part in clockwise for the drinking water flow
Perform the nozzle holes cleaning as showed, with the switched off machine
and insulated from the external feeding sources
Contact directly the Authorized Assistance Centre
Perform the cleaning as showed in the appropriate chapter
Insert on the drawer bottom so that the basin discharge happens completely
inside the drawer
Discharge pipe not inserted correctly or not blocked with strip
Pag.
di
15
17