8.5.2. Kwikco proofer electrical connection
This should be carried out by authorized professionals accor-
ding to regulations in the country in question.
A magnetothermic switch suitable for the total intensity should
be included in the electrical installation in the premises. The
device should be fitted with an electrical plug for disconnec-
tion (supplied with the proofer). Disconnect the plug from the
ELECTRICITY SUPPLY before manipulating the electrical parts
of the proofer.
NOTE: The electrical plug supplied with the proofer is Schuc-
ko European type and must be placed in an easily accessible
location.
Type
Model
V
A
Hz
Phases
kW
KXE-20+H
2010
230
5
50/60
I~
1.1
The proofer is supplied totally assembled and set for 230 V
single phase, plus ground connection. If the electrical supply
is 230 V three-phase, two phases plus ground should be con-
nected, and if it is 400 V three phase, one phase plus neutral
and plus ground should be connected.
The sections for two-phase cables plus ground be as follows:
Connection to 230 V.
Power
2 phases + ground
or
kW.
1 phase + neutral + ground
1.1
1.5 mm2