5. 5. Electrical connection
Electrical connection
salva
Connection
Power
kW
3 phases + ground
Circuit
Sections of
breaker
the cables
4 x 4 mm2
7.5
3 x 25 A
(3+T)
4 x 4 mm2
8.5
3 x 25 A
(3+T)
4 x 10 mm2
14.5
3 x 40 A
(3+T)
17
-6-
The electrical connection must be carried out by authorised
professionals, in line with the rules in force in the country where
the oven is to be installed.
Electrical cable must be used for the oven's electrical connec-
tions (the length supplied with the oven is 2.5m). The connec-
tion cable protrudes from the rear of the oven.
The customer must include a magnetothermic switch suitable
for the total intensity of the electrical installation in the premi-
ses, providing the omnipolar cut-off of the power cables.
The customer must fit a plug to the oven's power cable in or-
der to disconnect the oven.
The electrical plug must be easily accessible.
The oven's electrical connections should be protected with a
differential circuit breaker for a rated leakage current at 300
mA.
Three phase connections require three phases plus earth for
connection at 230 V. and three phases plus neutral and earth
for connection at 400 V .
THREE PHASE
230V
CEE
Circuit
connector
breaker
plug
32 A (3P+T)
3 x 16 A
32 A (3P+T)
3 x 16 A
63 A (3P+T)
3 x 25 A
3 x 32 A
Connection
400V
3 phases + neutral + ground
CEE
Sections of
connector
the cables
plug
5 x 2,5 mm2
16 A (4P+T)
(3+N+T)
5 x 2,5 mm2
16 A (4P+T)
(3+N+T)
5 x 4 mm2
32 A (4P+T)
(3+N+T)
5 x 6 mm2
32 A (4P+T)
(3+N+T)
Previas_Kwikco_10_(c-f-i)040511