Maintenance - Toto TLP01701U Manual De Instalación Y Del Propietario

Grifo automático
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Check your faucet at least once a month for the following potential problems
and to do the following maintenance procedures:
Inspect for Leakage
ƒ Check all water connections for signs of leakage.
Tighten the Spout
ƒ If the spout is loose, tighten the hexagonal nut underneath the spout.
Adjust the Temperature
ƒ For thermostatic mixing models, turn the temperature control handle a
few times a year. Buildup may form inside the valve, resulting in impaired
performance if maintenance is not regularly performed.
Cleaning the Nozzle Screen and Inlet Strainer
ƒ When the inlet strainer is clogged the flow rate will decrease. Decreased
flow rate can lead to diminished flow.
A
To clean the nozzle screen:
1.
Pull out the power plug and remove the two screws.
2.
Dismount the four parts.
3.
Remove the spacer and the nozzle screen.
4.
Scrub the nozzle screen gently with a tooth brush.
5.
Mount the parts in the reverse order in which they were dismounted.
6.
The nozzle screen and the flow-dividing plate must be assembled in a
specific order.
B
To clean the strainer:
1.
Close the water shutoff valve.
2.
Remove the lid and take out the strainer, using the special tool.
3.
Scrub the strainer gently with a tooth brush.
4.
Open the water shutoff valve.
Modifying the outlet flow
ƒ When modifying the flow regulator, the outlet flow control must be
serviced with only Toto's recommended flow rate of 1.1 gallon/min (4.2 L/
min).
MAINTENTANCE