Terminal board connections
7
CMN common for all inputs and outputs.
ELS electric lock output (fed continuously) 12 Vdc - 15 W.
8
9-10 LC-CH2 Potential free contact for the activation of the courtesy light (separate
power supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel. Selec-
tion is carried out using jumper "J5".
11 CMN common for all inputs and outputs.
12 LP 24 Vdc 25 W output for warning lights
intermittent activation (50%), 12,5 W continuous activation.
13 LS 24 Vdc 3 W output for an indicator light.
14 CMN common for all inputs and outputs.
15 24 Vdc controlled output, powering external loads
16 CMN common for all inputs and outputs.
17 24 Vdc output, powering external loads
18 TA (NO contact) opening button input.
19 TC (NO contact) closing button input.
20 TAL (NO contact) limited opening button input.
21 TD (NO contact) dynamic button input.
22 CMN common for all inputs and outputs.
23 TB (NC contact) stop button input (The opening of this contact interrupts the
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
cycle until a new movement command is given).
24 CSP (NC contact) safety edge input. Opening this contact will provoke a travel
direction inversion during the closing stage and during the opening stage
25 FTCS (NC contact) The opening of this contact will block all movement, until the
obstruction has been removed and the pause time has elapsed, due to the safety
device cutting in, the door will then continue moving in the closing direction (only
with automatic reclosing enabled).
26 FTCI (NC contact) safety and control devices in input (photocells invert the travel
direction when an obstruction is detected). Opening this contact will provoke a
travel direction inversion during closure due to the cutting in of the safety device.
27 EMRG2 (NO) emergency manoeuvre input 2.
28 EMRG1 (NO) emergency manoeuvre input 1.
29 CMN common for the emergency buttons.
30 Inner conductor for radio receiver antenna (if an external antenna is fitted use a
coaxial type cable RG58 with an impedance of 50Ω).
31 Outer conductor for radio receiver antenna.
3
10
J1
F3
L3
J2
10
Collegamento motori/encoder a 4 fili
Connecting motor/4-wire encoder
Branchement moteur/encodeur à 4 fils
Anschluss der Motor/Encoder mit 4 Drähten
Conexionado motores/encoder de 4 conductores
COLORE
CABLAGGI
Bl
Blu
Gr
Verde
Gy
Grigio
Yw
Giallo
KABELFARBEN
Bl
Blau
Gr
Grün
Gy
Grau
Yw
Gelb
ENCODER 1
M1
Bl
Gr
1
2
3
4
B1
Signal buzzer "via radio" mode
CSER
Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
F1
10A blade fuse
(motor power protection)
(6)
F2
10A blade fuse
(motor protection during battery operation)
(6)
F3
4A
blade fuse
(24V circuit protection)
(6)
F4
4A
blade fuse
(24V circuit protection during battery operation)
(6)
F5
4A
blade fuse
(electric lock protection)
(6)
J1
Battery connection
J2
Transformer secondary protection
Drawing number :
DC0441
Product Code :
CC24??????????
.
(1)
.
(1)
4A
F2
F4
L2
L1
F1
COLOUR CODE COLORATION
CODE
DES CÂBLAGES
Blue
Bleu
Green
Vert
Grey
Gris
Yellow
Jaune
COLORACIÓN
CABLEADOS
Azul
Verde
Gris
F5
Amarillo
ENCODER 2
M2
Gy
Yw
Bl
Gr
Gy
Yw
5
6
1
2
3
4
5
6
Description :
CENTRALINA 2 MOTORI CC CON ENCODER
Note
The total of the 2 external device outputs must not exceed 10 W.
(1)
Note
Jumper "J6" identifies the type of safety edge connected to binding post 24:
(2)
- in position 1 the safety edge with NC contact is selected;
- in position 2 the safety edge with 8.2 kΩ contact is selected;
If you bridge the CSP input, move jumper "J6" to position 1 (NC).
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the security
device test must also be deactivated (FTCI , FTCS - Dip 7 and Dip 8 "OFF").
If you want to activate the FTCI, FTCS test both the transmission and receiver parts of
the security devices must be connected to the binding post marked "CTRL 30 Vdc".
If the test is active there will be a 1 second delay between the command transmission
and movement of the gate/s.
Switch on the power and make sure that the LEDs are in the following condition.
- L1
Power on
- L2
Battery charging
- L3
Wrong battery connection
- L4
Transmitter code programming indicator
- L5
Indicator for the blocking button "TB"
- L6
Indicator for the inverting photoelectric cells "FTCI"
- L7
Indicator for the stop photoelectric cells "FTCS"
- L8
Indicator for the safety edge "CSP"
- L9
.
Indicator for the opening button "TA"
(2)
- L10 Indicator for the opening button "TC"
- L11 Indicator for the limited opening button "TAL"
- L12 Indicator for the sequential command "TD/CH1"
Note
: This LED is "ON" when the battery is charging.
(3)
Note
: If this LED is "ON" invert the battery power cables immediately.
(4)
Note
: Check that the activation of the safety devices switches the corresponding
(5)
LEDs off.
If the green power on LED "L1" doesn't light up check the condition of the fuses
and the power cable connection at the transformer primary.
If one or more of the safety LEDs do not light up check the contacts of the relative
security devices and check that the unused safety device contacts have been bridged.
J3
L5
L6
J4
L7
J5
DS1
TD
RA
1 2
PLP
P2
3
LP
LS
Pos.1 Pos.2
FTCI
L4
TFTI
TFTS
SAP
P3
ELS
LC/CH2
7
8
9
10
11
12
13
14
15
16
J3
Enable transmitter memorisation via radio
J4
Radio channel selection
J5
Binding posts 9, 10 selection (courtesy light/CH2 via radio)
J6
Safety edge selection CSP NC/8.2 kΩ
MM
Transmitter code memory module
P1
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
Note
: These are automotive type blade fuses (max. voltage 58 V)
(6)
Collegamenti scheda base
14
CS 1283
R1
DC 0406
B1
MM
L8
L9
L11
P1
D1
L10
L12
CSER
1 2
3
J6
1 2
1 2
3
3
CMN
Pos.1 Pos.2
EMRG 1
EMRG 2
17
18
19
20
21
22
23
24
25
ON
OFF
(3)
OFF
(4)
OFF
ON
(5)
ON
(5)
ON
(5)
ON
(5)
OFF
OFF
OFF
OFF