Protection

Operating condition
The protective device maybe trip and stop
the appliance in the cases listed below.
Outdoor air temperature is over 24 C
HEATING
Outdoor air temperature is below -7 C
Room temperature is over 27 C
Outdoor air temperature is over *43 C
COOLING
Room temperature is below 21 C
Room temperature is below 18 C
DRY
*For Tropical (T3) Climate condition models, the
temperature point is 52℃ instead of 43℃.
If the air conditioner runs in COOLING or DRY mode with
door or window opened for a long time when relative
humidity is above 80%,dew may drip down from the outlet.
The protective device will work at following cases.
Restarting the unit at once after operation stops or changing mode during operation, you need to
wait 3 minutes.
Connect to power supply and turn on the unit at once, it may start 20 seconds later.
If all operation has stopped, press ON/OFFbutton again to restart, Timer should be set again
if it has been canceled.
Preheat
At the beginning of HEATING operation, the airflow from indoor unit is discharged 2-5
minutes later.
Defrost
In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency.
This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation.
After defrosting completes, it returns to HEATING mode automatically.
Note: Heating is NOT available for cooling only air conditioner models.
Install the air conditioner at a place that
can bear its weight in order to operate
more quietly.
o
Install the outdoor unit at a place where
o
the air discharged and the operation noise
o
would not annoy your neighbors.
o
o
Do not place any obstacles in front of the
air outlet of the outdoor unit lest it increases
o
the noise level.
Features of protector
Features of HEATING mode
16
Noise pollution