IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING
Always turn off power at the main power supply
before installing, cleaning or removing the
thermostat.
Do not use on voltages over 12 VDC. Higher
voltages will damage the thermostat and could cause
shock or fire hazards.
All wiring must conform to local and national
electrical and building codes.
Use this thermostat only as described in this manual.
Specifications
Electrical Rating:
12 VDC (Operating Range from 10.5 VDC - 14 VDC)
Changing Units Between Fahrenheit (°F) and Celsius (°C):
Simultaneously hold the Temp +/- buttons for 2 seconds.
Operating Temperature Range:
0°F-115°F (-18°C-46°C)
Cooling Range:
60°F-85°F (15°C-30°C)
Heating Range
40°F-85°F (5°C-30°C)
Accuracy:
± 1°F (± 0.5°C)
Wall Thermostat Terminations:
0V (GND), Signal (COMMS), +12VDC
Wiring:
12 VDC Thermostat: Recommend AWG20 solid 3 copper wire
12 VDC Main Control: Recommend AWG18 stranded 2
copper wire
120 VAC Main Control: Recommend AWG12 solid copper
wire
49-5000400 Rev. 2
FIRE AND SHOCK HAZARD