Specifications
Process Application
Application
Measurement Range
Vessel Pressure
Operation
Beam Angle
Frequency
Temperature Sensor
Supply Source
Environmental
Location
Ambient Temperature
Maximum Altitude
Pollution Degree
Construction
Housing
Mounting
Cabling
Cable Type
Maximum Separation from
Transceiver
Miscellaneous
Ingress Protection
Weight*
Options
Approvals
* Approximate shipping weight of transducer with standard cable length.
** Performance available upon request.
7ML19985QT81
XRS-5 Series Transducers – OPERATION MANUAL
XRS-5
Liquids and Slurries
0.3 - 8 m (1 - 26 ft)
Vented to atmosphere
10
43 KHz
Internal
Transducer shall only be supplied
by Milltornics certified controller
indoor/outdoor
-20 to 65 °C (-4 to 149 °F)
2000 m
4
• PVDF body and CSM face
1" NPT or BSP conduit connection
2-wire shielded/twisted, 0.5mm
(18 AWG) PVC jacket
• 365 m (1200 ft) using RG-62 A/U
coaxial cable
• 365 m (1200 ft) using 2-wire
twisted pair/braided and foil
2
shielded 20 AWG (0.5mm
), PVC
jacket (EnviroRanger ERS 500,
MultiRanger 100/200, and
HydroRanger 200 only)
IP68
1.2 kg (2.6 lb)
• Factory flanged to suit ANSI,
DIN, or JIS standard
• Split flange (field mount) to suit
ANSI, DIN, or JIS standard
• Submergence shield (flooding
applications)
CE**, CSA, FM, CENELEC/ATEX,
SAA, see device nameplate
XRS-5C
Liquids and Slurries
0.3 - 8 m (1 - 26 ft)
Vented to atmosphere
10
43 KHz
Internal
Transducer shall only be supplied
by Milltornics certified controller
indoor/outdoor
-20 to 65 °C (-4 to 149 °F)
2000 m
4
• PVDF body and CSM face
• Stainless steel conduit
connection
1" NPT conduit connection
2
2-wire shielded/twisted, 0.5mm
(18 AWG) PVC jacket
• 365 m (1200 ft) using RG-62 A/U
coaxial cable
• 365 m (1200 ft) using 2-wire
twisted pair/braided and foil
shielded 20 AWG (0.5mm
jacket (EnviroRanger ERS 500,
MultiRanger 100/200, and
HydroRanger 200 only)
IP68
1.2 kg (2.6 lb)
• Factory flanged to suit ANSI,
DIN, or JIS standard
• Split flange (field mount) to suit
ANSI, DIN, or JIS standard
• Submergence shield (flooding
applications)
CSA, see device nameplate
2
2
), PVC
Page EN-3