Two-Way Voice; Zone Attributes; Notifications; Not Supported - DSC IMPASSA TL8055LT Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Table 1-1 Panel settings
Section Option
015
7
301
--
302
--
303
--
305
--
310
--
350
1st Telephone Number Communicator format options
350
2nd Telephone Number Communicator format options
381
3
381
7
383
2
383
8

Two-way voice

Section [600] option [8] controls how the CS operator initiates the 2-way audio session. Set to ON for the ses-
sion to be initiated by the operator. Set to OFF for the session to begin immediately after the siren turns off.
Note: The two-way voice feature was not evaluated by UL/ULC.

Zone attributes

Sections [101] through [164] control the attributes for each zone. Option [5] enables or disables Force Arming.
If this option is set to OFF, the system cannot be armed if the zone is opened.
Note: Remote arming from Alarm.com will automatically prompt to bypass open zones that have the Bypass
attribute enabled. Only compatible with IMPASSA V1.31+ and IMPASSA Communicator V181.5+.

Notifications

The following panel settings may alter the behavior of customer notifications:
Table 1-2 Panel settings
Section Option Description
015
4
015
8

Not supported

The following panel settings are either handled automatically or not supported and so any changes to them will
be ignored:
Table 1-3 Panel settings
Section(s) Option(s)
324-348
All
377
Swinger Shutdown (Tampers and Rest) Max. number of transmissions
377
Swinger Shutdown (Maint. And Rest) Max. number of transmissions
600
1-7
601
All
609-611
All
Description
Telephone line monitoring
Communication telephone numbers
Communication telephone numbers
Communication telephone numbers
Communication telephone numbers
System account number
Reporting codes
Reporting codes
Telephone number backup options
Remote notification format
If this option is ON, keyfob arming notifications will not be associated with a specific user
If this option is OFF, notifications will not be available for panel tampers. Set to ON to enable
tamper notifications
Description
Custom reporting codes
2-way Audio control
2-way Audio control
Reporting codes
- 11 -
Alarm.com LTE

Capítulos

Tabla de contenido
loading

Tabla de contenido