Operating Modes - Ferroli RIMINI DP Instrucciones Para La Instalación Y El Uso

Emisores térmicos eléctricos digitales programables
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5.3. Operating modes

By successively touching the mode key the radiator is changed from one mode to another.
To identify the mode a screen is initially displayed for 2 seconds.
COMFORT:
The first mode of operation that appears when the radiator is connected for the
first time, and changed from Standby to operational, is "comfort".
In this mode, the desired room temperature is selected by
tween 12 °C and 30 °C in steps of 0.5 °C (if the keys are held, the temperature
changes faster). When the temperature reaches either the maximum or minimum
value it will stop.
Typical comfort temperature is 20 - 21 °C. The comfort mode is normally used
during the hours the room is occupied.
ECONOMY:
The next mode that appears is "economy", which automatically sets a tempera-
ture between 0.5 °C and 4.5 °C less than the previously selected comfort temper-
ature (the difference can be directly set by the user with the
When the comfort temperature is raised or lowered, the eco temperature auto-
matically rises or falls by the set amount.
While the comfort temperature can be set from 12 °C to 30 °C, the ECO tempera-
ture is from 7.5 °C to 29.5 °C, but always between 0.5 °C and 4.5 °C below the
comfort temperature.
Economy mode is used for short absence periods to prevent the temperature
from falling excessively.
ANTI-FROST:
PROGRAM:
In Program mode, the radiator automatically switches between the 3 mode tem-
peratures according to the daily and weekly program set by the user.
The program circle is displayed permanently and displays the 12 hours program
divided into half-hour intervals. The circle in which the current time is, is dis-
played, from 00:00 to 11:59 and from 12:00 to 23:59. Each half-hour interval of
each day of the week can be programmed as comfort, eco or anti-frost mode.
The icon of the current half hour flashes to indicate to the user what the current
set point is.
56
MODE
In this mode, the temperature setting is 7 °C and is factory set.
Anti-frost is usually used as an off set point and for long periods
of absence when you want to avoid freezing.
EN
MODE
MODE
RIMINI DP
and
keys, be-
and
keys).
A73021552
Tabla de contenido