2. INSTALLATION

2.1 POSITIONING THE AIR CONDITIONER
To maintain the best performance from your air conditioner, prevent breakdowns or hazards, you must position it
correctly. P lease follow the guidelines and instruction below in full, as failure to do so could cause potential
installation problems.
-The air conditioner must be installed on an exterior wall that has access to the out side with a minimum of 2 meters
clearance to the outside.
-The air conditioner must be fitted leaving room all around as illustrated in the paper template -The wall on which the
air conditioner is installed must be sturdy and able to withstand the weight of the air conditioner.
After determining the best place for installation as described above, please check to ensure that the w all can be
drilled in the chosen area without interfering with other structures or installations (beams, piers, pipes, wires, etc.).
Indoor
Outdoor
2 m
2 m
Note:
Please also ensure that there are no obstacles on the outside of the wall, which may obstruct air circulation through
the drilled holes, for example: plants and their leaves, slats or panelling, drain pipes, overflows and gratings, etc.).
Any obstruction could interfere with the correct performances of the air conditioner.

2.2 PAPER TEMPLATE

Fasten the template to the wall once the lowing guidelines have been thoroughly checked.
- Do not drill any holes until you are completely confident that there are no obstacles in the area you wish to drill and
there are no obstructions, which could be hidden by the construction of the wall, for example:
Electrical wiring water & gas pipes or supporting lintels or beams.
- Ensure that a spirit level is used, as the air conditioner must be level.
- Follow the installation instructions in full.
Spirit livel

2.3 DRILLING THE WALL

Please note: If you are drilling the hole above ground floor level, please ensure that an area has been secured and
while the holes are drilled the outside area is supervised, until drilling has been completed.
INTAKE AND OUTLET HOLES
- This operation should be carried out using the proper tools (diamond tip or core borers drills with high twisting
torque and adjustable rotation speed).
- Fasten the template to the wall taking care to check the distance from the floor and or ceiling and keep it horizontal
by using a spirit level.
- Use a pilot drill to mark the centre of each core hole to be drilled.
Use a core boring head having a diameter of 162 mm to drill the two holes for intake and outlet the air.