ENGLISH
DC CURRENT 200mA to 10A
1. For DC currents more than 200mA and less than 10A, insert
RED test lead into 10A jack
jack
, and rotate function selector switch
4
10A DC setting.
Red lead Black lead
DC CURRENT LESS THAN 200mA
2. For mA DC currents less than 200mA, insert RED test lead into
V jack
5
function selector switch
Black lead
3. To measure current: Remove power from circuit, open circuit at
measurement point, connect meter in-series in the circuit using
the test leads, and apply power to circuit.The meter will auto-
range to display the measurement in the most appropriate range.
NOTE: If measuring mA, the function selector switch
rotated to successively lower mA DC settings to obtain higher
resolution measurements.
Do not attempt to measure more than 10A.
When measuring currents greater than 6A, a measurement
time of 30 seconds followed by 10 minutes of recovery time
is recommended.
8
OPERATING INSTRUCTIONS
, and BLACK test lead into COM jack
2
Red lead
, and BLACK test lead into COM
3
to the highest mA DC setting (200mA).
to the
2
, and rotate
4
may be
2