2. Guarantee
For guarantees please refer to the
respective terms and conditions of
supply for your country.
The installation, electrical
connection and first
operation of this appliance should be
carried out by a qualified installer.
3. Fault elimination for the user
Fault
No hot water despite flow volume
setting at
"Trip" - light on
The unit is not being switched
on. Electricity supply and flow
available.
STIEBEL ELTRON
The company does not accept liability
for failure of any good supplied
which have not been installed and
operated in accordance with the
manufacturer's instructions.
Cause
The water flow volume
required for the unit to
turn on has not been
reached.
- The shower head is
blocked with
dirt or limescale.
- Flow volume too low.
- ELSD activated
The water flow volume
required for the unit to
turn on has not been
reached.
- Filter in the cold water
connection pipe blocked
with dirt.
- Water pressure not
enough
Rectification
- Clean shower head
or remove limescale.
- Increase flow volume.
- Press "Reset" - button.
- Clean the filter after
shutting off the cold
water intake.
- Increase mains
pressure
5