60
AVENTICS | ED12 | R414002587–BDL–001–AB
Technical data
Table 12:
Malfunction
Air is audibly escaping
ED12 does not exhaust
ED12 emits short pressure
pulses
Table 13:
General
Dimensions (width x height x depth)
Weight
Operating temperature range
Storage temperature range
Controlling
Model
Permissible medium
Possible cause
Base plate seal is missing or
damaged
Leaks between the ED12 and
base plate
ED12 is not leaktight
Pneumatic connections on the
base plate exchanged
Exhaust connection on the base
plate is closed
Device with current input is
operated with voltage set point
12 Technical data
254 mm x 100 mm x 55 mm
2.3 kg
5°C to 50°C
–20°C to +80°C
Analog
Poppet valve
Air with quality class DIN ISO 8573-1
For solid impurities:5
For water content:3
For total oil content:1
Remedy
Check the base plate seal and
exchange, if necessary
Tighten screws with 6 Nm torque.
Exchange the ED12
Connect the pneumatics on the base
plate correctly (see "Connecting the
base plate pneumatics" on page 52)
Open the exhaust connection and
connect a silencer or restricted
exhaust hose
Stipulate the correct type of set point