Risk due to incorrectly mounted device!
An incorrectly mounted device may result in uncontrolled movements that could damage
other system parts.
Make sure that the device is attached to a base plate that is securely fastened to the
machine or a mounting plate.
Malfunction caused by closed housing ventilation port!
If the housing ventilation port is closed, there is no atmospheric equalization and the
characteristics curve will change.
Ensure that the air can circulate freely through the housing ventilation port (2).
Never operate the device in an atmosphere containing oil.
AVENTICS | ED12 | R414002587–BDL–001–AB
NOTICE
Mount the base plate in a control cabinet or on a mounting
plate.
A vertical mounting orientation is preferred for the ED12.
18
Abb. 5: Mounting orientation
18 Vertical axis
19 Horizontal axis
The device can be mounted in any orientation if the compressed air
is dry and oil-free.
NOTICE
47
Assembling the ED12
19
00122956